KHIA ID: 7602Industry: Power (POWR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Cast ironCustomer Location: Power station, Slovakia
Application Date: 2014Products:Belzona 1311 (Ceramic R Metal)
Belzona 1341 (Supermetalglide)
Problem: This pump had been in service for 35 years and was suffering erosion corrosion damage due to constant water flow.
1. TG pump
2. Damaged area
3. After blasting
4. After Belzona 1311 and Belzona 1341 application.