Wind Turbine Bedframe Repaired with Belzona
Industry: Power (POWR)
Application: GSS-Gaskets, Seals and Shims (GSS)
Substrate: Carbon steel
Customer Location: Scotland
Application Date: April 2022
Products: Belzona 1111 (SuperMetal),
Problem: Welding was undesirable due to the risk of heat distortion in the large metal casing. Any repair needed to withstand the high compressive loads.
Metal loss shown on the casing
Power tool preparation on the damaged surfaces
Belzona 1111 built up proud of casing
The Belzona 1111 machined flat with the surrounding metal
Application Situation
A wind turbine nacelle bedframe had become damaged through corrosion. The corrosion had formed pitted areas where the main shaft pedesal is landed. A flat surface was required to bolt onto with no gaps where water could ingress & cause future corrosion.
Application Method
The application was carried out in accordance with Belzona System Leaflet GSS-06. The area was first prepared with an angle grinder & MBX Bristle Blaster. The Belzona 1111 Supermetal was then applied proud of the surrounding metal. Once it reached its initial cure stage it was then sanded down flat with the undamaged sections of the casing.
Belzona Facts
The Belzona repair was carried out without the risk of distortion of the casing. Once cured the product has a very high compressive strength, it also does not corrode in normal conditions so it will prevent future corrosion if water does reach the area.