BELZONA EMERGENCY LEAK SEALING: THREE HOURS LATER - IT’S READY

KHIA ID: 450
Industry: General Industry (GIND)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon steel
Customer Location: Fertilizer producer in Egypt
Application Date: October 2003
Products:

Belzona® 1111 (Super Metal)

Belzona® 1291 (ES Metal)


Problem: Corrosion of vessel had caused leak.
Photograph Descriptions
  1. Belzona® 1291 used in conjunction with metal clamp to initially stem the leak
  2. Belzona® 1111 plus Belzona® 9341 (Reinforcement Tape) applied to strengthen the repair
  3. Repair completed in 3 hours
Application Situation
Natural gas separator operating at 43 bar pressure
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-1.
Belzona Facts
Belzona® 1291 was initially used in conjunction with a metal clamp to stem the leak before applying Belzona® 1111 with Belzona® 9341 (Reinforcement Tape) to complete the application. Repair completed quickly and safely without heat so preventing the need for a major plant shut-down.