BELZONA QUICKLY RESTORES & UPGRADES TURBINE PROTECTION

KHIA ID: 1896
Industry: Power (POWR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Steel
Customer Location: Hydropower plant, France
Application Date: 2011
Products:

Belzona® 1341 (Supermetalglide)

Belzona® 2141 (ACR-Fluid Elastomer)

Belzona® 5811 (Immersion Grade)


Problem: The client wished to renew the coating so as to maintain erosion corrosion protection
Photograph Descriptions
  1. Blasted runner prior to the application
  2. Mixing of Belzona® 2141
  3. Application of Belzona® 2141
  4. Completed equipment
Application Situation
A Francis turbine runner which had been previously coated 15 years ago.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet CEP-3.The bottom and top parts only needed a protection against corrosion and not erosion: Belzona® 5811 was used. The middle part had a serious problem of cavitation: Belzona® 1341 and Belzona® 2141 were used.
Belzona Facts
The equipment was coated on time and put back into service with minimal delay. Use of Belzona® 2141 System will provide improved resistance to cavitaion over previously used coating.