BELZONA REPAIRS HOLE ON SCUM TANK

KHIA ID: 5827
Industry: Water / Wastewater (WATR)
Application: HEX-Heat Exchangers (HEX)
Substrate: Steel
Customer Location: Toronto, ON, Canada
Application Date: November 2014
Products:

Belzona 1161 (Super UW-Metal)

Belzona 9111 (Cleaner Degreaser)


Problem: Hole caused by corrosion.
Photograph Descriptions
  1. Prior to application
  2. Preparation in progress
  3. Application in progress
  4. Completed application
Application Situation
Scum tank at a water pollution control plant.
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflet HEX-9 for repairing leaking pipework. The surface was prepared using a grinder to roughen the surface and Belzona 9111 was used to clean the area. Belzona 1161 was applied around the hole and then a piece of metal was placed over the product. Once the piece of metal is in place, Belzona 1161 was applied around the pipe in accordance with Belzona Instructions For Use.
Belzona Facts
Belzona 1161 bonds firmly to oily, wet and not fully prepared substrates. This system is simple to use and does not require specialist tools. By using Belzona 1161, the customer eliminated expensive replacement costs and minimized downtime.