Belzona® 2000 Series (Elastomeric Polymers)


問題: The SF6 dielectric gaseous insulator was leaking from the flange.
写真の説明
  1. Belzona® 2211 (MP Hi-Build Elastomer) was injected between flanges to fill the gap. 
  2. Completed application.
  3. Various leaking flanges were sealed
アプリケーションの状況
Flanges of SF6 (sulfur hexafluoride) buss bars.
塗布方法
The application was carried out in accordance with Belzona Know-How Leaflet GSS-4.
Belzonaの事実
Since the customer realized significant cost savings, several leaks were repaired. Four and one-half years later the original repair is still holding.