Cooling Water Head Brought Back To Life With Belzona 1391T

KHIA ID: 9661
Industry: Oil & Gas (OILG)
Application: HEX-Heat Exchangers (HEX)
Substrate: Carbon steel
Customer Location: Texas
Application Date: January 2018
Products: Belzona 1111 (Super Metal),Belzona 1391T

Problem: Customer pulled several HEX for routine inspections and discovered bad pitting on one the Cooling Water Heads. They were in a small Pit-Stop and had 3 days to get this repaired and back in service.

Cooling Water Head Before

Cooling Water Head After

Application Situation
This was an emergency for the customer as they could not restart this unit without their cooling water HEX. We were able to load the head and take it to our shop. Blast and coat and return in 24 hours.
Application Method
We blasted and filled pitting with 1111, coated with 2 coats of 1391T.
Belzona Facts
Save the customer thousands of dollars by getting this back and not delaying the startup process.