KHIA ID: 9565Industry: Marine (MRNE)
Application: FPA-Floor Problem Areas (FPA)
Substrate: Carbon steelCustomer Location: Ontario
Application Date: May 2023Products: Belzona 1111 (Super Metal)
Problem: Several holes on a ship deck required patching before being sent out to the museum. Customer did not want to bond a plate to entire surface because of cost implications. Belzona 1111 was used to patch the holes individually after required surface cleaning procedure and coated afterwards.
Deck during inspection
Deck after application of Belzona 1111
Entire deck after weeks of application,