LOWER HALF OF KNOCK OUT VESSEL PROTECTED WITH BELZONA
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Oil Refinery-Australia
Application Date: May 2004
Products:
Belzona® 1311 (Ceramic R-Metal)
Belzona® 1391 (Ceramic HT Metal)
Problem: Internal erosion corrosion in lower section caused by sour water. Vessel regularly steamed out.
Photograph Descriptions
- Typical limited access to vessel through manway
- Application of Belzona® 1391 underway
- Completed application
Application Situation
Liquid knock out for flare gases. Also exposed to MEK, Toluene and gasoline.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-5. Belzona® 1311 was used to repair pitting (particularly in 4-8 o’clock positions) and to smooth out weld repairs after which the lower half of the vessel was coated with Belzona® 1391.
Belzona Facts
Previous coating had failed. Belzona had previously been used for local repairs before this shut-down and had proven itself in the environment.