LOWER HALF OF KNOCK OUT VESSEL PROTECTED WITH BELZONA

KHIA ID: 489
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Oil Refinery-Australia
Application Date: May 2004
Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1391 (Ceramic HT Metal)


Problem: Internal erosion corrosion in lower section caused by sour water. Vessel regularly steamed out.
Photograph Descriptions
  1. Typical limited access to vessel through manway
  2. Application of Belzona® 1391 underway
  3. Completed application
Application Situation
Liquid knock out for flare gases. Also exposed to MEK, Toluene and gasoline.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-5. Belzona® 1311 was used to repair pitting (particularly in 4-8 o’clock positions) and to smooth out weld repairs after which the lower half of the vessel was coated with Belzona® 1391.
Belzona Facts
Previous coating had failed. Belzona had previously been used for local repairs before this shut-down and had proven itself in the environment.