PROTECTION OF BOILER FEED PUMPS WITH BELZONA® 1391

KHIA ID: 149
Промышленность: Chemical & Petrochemical (PETR)
Заявление: CEP-Centrifugal Pumps (CEP)
Субстрат: Steel
Местоположение клиента: Chemical Plant in Poland
Дата подачи документов: September 1995
Продукты:

Belzona® 1391


Проблема: Erosion on the impellers and casing.
Описание фотографий
  1. Application underway on one of the impellers. 
  2. Application complete. 
  3. Pump in service
Ситуация с приложением
Six stage boiler feed pumps operating at 105°C (220°F) and 50 bar pressure at 2950 rpm.
Способ применения
Application carried out in accordance with Belzona Know-How system CEP-3.
Белзона Факты
A total of five pumps have now been coated and original pump is still performing satisfactory after four years in service.