REPAIR OF SEA WATER INLET VALVE WITH BELZONA

KHIA ID: 8157
Industry: Marine (MRNE)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Rubber
Customer Location: Shipyard, ISTANBUL, TURKEY
Application Date: June 2018
Products:

Belzona 2211 (MP Hi-Build Elastomer)

Belzona 2911 (Elastomer QD Conditioner)


Problem: Sea water inlet valve sealing rubber surface has been damaged. Valve is not sealing properly.
Photograph Descriptions
  1. Damaged surface of the valve. 
  2. After surface preparation. 
  3. Application of Belzona 2911. 
  4. Application of Belzona 2211.
Application Situation
Ship sea water inlet valves.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet VPF-03. Damaged rubber surface was undercut and abraded to achieve a mechanical bond. The surface was conditioned with Belzona 2911 and allowed the cure. Then Belzona 2211 was applied and allowed to cure.
Belzona Facts