Structural reinforcement of weakened pipe in a wastewater plant
Industry: Water / Wastewater (WATR)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Carbon steel
Customer Location: Ontario
Application Date: August 2021
Products: Belzona 1161 (Super UW-Metal),Belzona SuperWrap II
Problem: The existing pipe had become severely weakened over time and they needed to reinforce it to prevent future problems.
Defective pipe in need of reinforcement.
Plate bonding over the most critical area.
Applying SuperWrapII to strengthen the entire pipe section.
Application Situation
Since this section was in a hard-to-reach area, replacing it would have been challenging. The Belzona solution enabled them to repair the pipe while it remained in service.
Application Method
The substrate was prepared using power tools. Due to severe deterioration of the bottom section, we decided to add a bonded plate for extra reinforcement. Following that, we applied three wraps of Belzona for complete structural reinforcement
Belzona Facts
The Belzona solution allowed the wastewater plant to repair the pipe without shutting it down, saving both time and money by avoiding expensive replacements and downtime. Unlike traditional methods, such as welding or full pipe replacement, which would have required a shutdown, Belzona's plate bonding and wrap system provided structural reinforcement while the pipe remained in service, offering a fast, effective, and durable repair.