BELZONA PROTECTS SLUG CATCHERS AGAINST EROSION AND CORROSION
Industry: Oil & Gas (OILG)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Vessel manufacturer in Italy
Application Date: September 2001
Products:
Belzona® 1391 (Ceramic HT Metal)
Problem: Vessels were to be put into operation at 90°C and 70 barpressure in a mixture of hydrocarbons and water. Belzona was applied to the bottom third of the vessels where the water gathers and causes corrosion.
Photograph Descriptions
- Two of the slug catchers ready for internal coating.
- The Belzona® 1391 being applied.
- Sponge testing the Belzona® 1391 to ensure no application defects were present in the coating.
Application Situation
Slug catchers destined for gas processing plant
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-3. Particular care was taken to maintain temperature of the substrate during application.
Belzona Facts
The Belzona® 1391 after 2 years in service was replaced due to increased use of acid for well stimulation. Belzona® 1392 has been developed to deal with this specific type of situation where acid contamination occurs.