BELZONA REPAIRS MEG TANK HOLED BY CUI

KHIA ID: 952
Industry: Oil & Gas (OILG)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon Steel
Customer Location: Oil Major St Fergus Gas plant, Scotland
Application Date: May 2006
Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)

Problem: Corrosion Under Insulation (CUI) on the vessel had caused a pin hole in the vessel wall
Photograph Descriptions
  1. CUI with pinhole drilled, threaded and bolted
  2. Application of Belzona® 1111
  3. Completion of the Application of the Belzona® 1111 externally
  4. Application of Belzona® 1111 & 1321 internally over the bolt
Application Situation
Glycol (MEG) Water tank had been put out of commission due to springing a leak
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-1
Belzona Facts
Hot work was not allowed on site without a major shut down. Belzona sealed leak and provided protection to surrounding area to prevent future problems of CUI.