BELZONA SOLVES FLAP VALVE DAMAGE

KHIA ID: 1231
Industry: General Industry (GIND)
Application: SHM-Solids Handling Machinery (SHM)
Substrate: Aluminum/Rubber
Customer Location: Door Component Plant, Central Missouri
Application Date: May, 2008
Products:

Belzona® 1812 ( Ceramic Carbide FP)

Belzona® 2111 (D&A Hi Build Elastomer)


Problem: The valves suffered damage on the back of the valve plate due to impact with the valve "stop". This impact would cause breakage/failure of ceramic tiles on the front of the valve, allowing gypsum/perlite mix to cause abrasion damage and prevent valve from sealing upon closure leading to repeated outages of the system.
Photograph Descriptions
  1. Valve plate showing impact damage on back from striking the valve stop 
  2. Striker plate and valve plate prepared for application
  3. Striker plated bonded to back of valve plate with Belzona® 2111
  4. Ceramic tile repaired with Belzona® 1812 on one valve, tile replaced with Belzona® 1812 on second valve
Application Situation
Flap valves used in gypsum/perlite transfer system. the valves were lined with ceramic tile.
Application Method
Application was carried out in accordance with Belzona Know Show System Leaflet SHM-7. Belzona® 2111 was used to bond a stainless steel striker plate to the back of the valve plate to absorb and distribute the sharp point impact from the valve stop. Belzona® 1812 was used to repair valve with broken tile and ultimately replace tile altogether for abrasion resistance on front of valve. 
Belzona Facts
After 7 months in service, valve plates show no signs of damage, compared with average life of 1-2 months before failing prior to Belzona Solution. Based on this success, customer has extended use of Belzona® 1812 and 2000 series products to many other applications throughout the plant.