Belzona Solution for Corroded Riser Casing

KHIA ID: 7983
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Gulf of Thailand
Application Date: 2018
Products:

Belzona 1111 (Super Metal)

Belzona 1982 

Belzona 9381 

Belzona 9611


Problem: Leaked and severe corroded surfaces were observed on splash zone of riser casing.
Photograph Descriptions

1. Corroded Riser Casing

2. Rebuilding with Belzona 1111

3. Superwrap 2 Application

4. Completed Application

Application Situation
Offshore riser casing required a solution to extend service life
Application Method
Repair parameters, repair thickness, number of wrap and wrapping length have been calculated from operating condition of the pipe which are provided by customer. Surface has been prepared with garnet grit to achieved SA 2 1/2 level of cleanliness and roughness more than 75 microns. Leaked or through wall defects were stopped by Belzona 9611 then rebuilt corroded surfaces with Belzona 1111 then SuperWrap II repair system was applied by using Belzona 1982 SuperWrap II Resin with Belzona 9381 reinforcing fiber.
Belzona Facts
Customer very impress in performance of Belzona SuperWrap II system which can help them to reduce downtime by online application. Wrapping process has been completed in 2 days.