Belzona extends the life of a CRF wheel

KHIA ID: 7896
Industry: Power (POWR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Cast iron
Customer Location: France
Application Date: 2005
Products:

Belzona 2311 (SR Elastomer)

Belzona 2141 (ACR-Fluid Elastomer)


Problem: The coating and the equipment were damaged by cavitation.
Photograph Descriptions

1- Before application

2- After application

Application Situation
Blades on a CRF wheel in a nuclear power plant.
Application Method
Application was carried out in accordance with Belzona System Leaflet CEP-05.
After the removal of the remaining patches of the previous coating, the substrate was rebuilt using Belzona 2311. Belzona 2141 was then used to protect the area against cavitation.
Belzona Facts
The customer noticed that the service life of this equipment was tripled thanks to this application. This solution would last 3 years instead of 1 with the alternatives tested before (welding, ceramic tiles, ...). This application is now done by the distributor every 3 years on this equipment.