Belzona provides cavitation repair and protection for a large hydropower unit impeller

KHIA ID: 9115
Industry: Power (POWR)
Application: FBC-Fans, Blowers and Compressors (FBC)
Substrate: Stainless-steel
Customer Location: a large hydropower plant in Hunan, China
Application Date: March 2022
Products: Belzona1311, Belzona1341, Belzona2141, Belzona2941,

Problem: Cavitation occurs at the top of Francis impeller in a hydropower station unit

the image of affected impeller

Pitting corrosion before repair

the surface after Belzona 1341 application

application completed

Application Situation
The hydropower station locates in the main stream of Yuan River, the capacity of which is 2.4 million kW.
Application Method
The application was carried out in strict accordance with Belzona Know How leaflets FBC-1 and FBC-2. Belzona 1311 was used to repair the cavitation areas after grit blasting. Then, applied two coats of Belzona 1341 to improve fluid efficiency for the equipment. Finally, Belzona 2941 and Belzona 2141 were applied to protect the outer surface against cavitation and corrosion.
Belzona Facts
The impellers have been affected by cavitation for many years. In the past, they were repaired by welding every two years. After a period of time, cavitation occurred again. This caused repeated deformation of the impellers, resulting in power generation efficiency decrease and increasing maintenance frequency and maintenance time. One year after the application of Belzona 2141, the impellers have been checked and witnessed few cavitation of Belzona 2141. Overall, the impellers were well protected and clients were satisfied.