Belzona 5831 (ST-Barrier)


Problem: The water circulating in this equipment was treated with CO2 and other additives against legionella causing an important problem of corrosion.
Photograph Descriptions

1- Before surface preparation

2- After surface preparation

3- Overview of the air-cooling equipment

4- Final application

Application Situation
Chassis of a gear reducer on an air-cooling system in a nuclear power plant.
Application Method
Application was carried out in accordance with an adapted version of Belzona System Leaflet FBC-2. The substrate was first prepared with a needle gun and grit blasted.Then, one coat of Belzona 5831 was applied (600microns).
Belzona Facts
Because of the corrosion, this chassis needed to be replaced using a 700 tonne crane which is not convenient, really expensive and causes an important loss of production. Belzona products were used in-situ and provided a long-term protection thus avoiding the replacement of the chassis.