SuperWrap II application to GFRP Spools

KHIA ID: 9364
Industry: Power (POWR)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: GFRP
Customer Location: Uniper UK Limited
Application Date:
Products: Belzona 1111 (Super Metal), Belzona 1983 (SuperWrap II)

Problem: Deteriorated / aged GFRP pipe spools that in turn have cracked at the flange to pipe spool area and are leaking

GRP Pipe Showing Crack

Plates cold bonded over cracked area

SuperWrap II In progress

Wraps Completed

Application Situation
This application provided a fast turnaround (4 working days) which meant minimal impact on site functions
Application Method
Frost blasted using conventional blasting within the BUK blast facilities. Cold plate bonded using Belzona 1111 (Super Metal)then SuperWrap II applied utilising 84mm wide sheet due to geometry.
Belzona Facts
GRP can be brittle and prone to cracking or breaking under sudden impact. This can be a concern in applications where the material is exposed to high stress or impact loads. By applying our SuperWrap II system these concerns can be eliminated.