BELZONA REBUILDS WASTEWATER PUMP IMPELLER

KHIA ID: 1116
Industry: Water / Wastewater (WATR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Steel
Customer Location: Water treatment plant, Des Moines, Iowa U.S.A.
Application Date: May 2008
Products:
Belzona® 1111 (Super Metal)
Belzona® 1321 (Ceramic S Metal)

Problem: The impeller was badly eroded and damaged due to grit and solids running through the pump
Photograph Descriptions
  1. Damaged impeller after being baked and grit blasted
  2. Impeller with wire mesh in place to support Belzona and help form profiles
  3. Profiles restored with Belzona® 1111
  4. Rebuilt impeller being balanced
Application Situation
Pump impeller handling raw water.
Application Method
The applications was carried out in accordance with Belzona Know-How System Leaflet CEP-1 & -3.
Belzona Facts
Belzona was chosen to rebuild the impeller at a fraction of the replacement cost.