Belzona Refurbishes old weathered industrial roof

KHIA ID: 8280
Industry: Commercial Facilities (COMM)
Application: RPA-Roof Problem Areas (RPA)
Substrate: Roofing Asphalt
Customer Location: Miami, Florida. USA
Application Date: April 2020
Products:

Belzona 3911

Belzona 3921

Belzona 3111

Belzona 9311


Problem: Numerous water leaks and deteriorated roof
Photograph Descriptions
  1. Roof before product application
  2. Surface preparation via pressure cleaning
  3. Mesh being applied over joint
  4. The finished area
Application Situation
The raining season was about to begin and this roof had several leaks and deteriorated areas that were potentially going to become problematic
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflets RPA-1 and RPA-8. Surface was cleaned via pressure washing. Belzona 3911 was applied with a brush as a primer over the entire roof and belzona 3921 was applied over any metallic substrate. Belzona 3111 was spray applied over the horizontal surfaces and brush applied over seams and difficult geometries. Belzona 9311 sheet was additionally applied to problem areas such as joints, seams and glazing bars as additional reinforcement.
Belzona Facts
Belzona 3111 was chosen over other alternatives solutions because of their compliance with stringent standard ASTM D6083. The owner was very pleased with the final outcome and is thinking of progressively coating all of their roofing areas.