Common problem within Pharmaceutical industry
Industry: Pharmaceutical (PHAR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Concrete
Customer Location: Dublin, Ireland
Application Date: January 2023
Products: Belzona 4361, Belzona 4911 (Magma TX Conditioner)
Problem: Several deep cracks in concrete around bund area.
Clears signs of chemical damage on bund floor
Failure of tank base seals leading to moisture ingress
Repairs with 4131 and sealing of cracks with 4361
Application Situation
Several deep cracks causing leaks in bund area.
Application Method
- Area was cleaned of debris and an abrasive wheel was used to provide a rough surface for the purpose of adhesion.
- Belzona 4911 applied as a conditioner and allowed to dry.
- Initial coat of Belzona 4361 applied and allowed to become touch dry.
- Second coat was applied after 4 hours.
Belzona Facts
Cracks were reoccurring due to repairs using traditional coatings.
The distributor were able to offer a flexible coating which provided a long lasting solution preventing reoccurrence of the problem.