Pump plinth rebuild

KHIA ID: 9622
Industry: Steel & Metal Processing (STEL)
Application: FPA-Floor Problem Areas (FPA)
Substrate: Masonry
Customer Location: Limerick, Ireland
Application Date: September 2024
Products: Belzona 1391 (Ceramic HT),Belzona 4131 (Magma-Screed),Belzona 4181 (AHR Magma-Quartz),Belzona 4911 (Magma TX Conditioner),Belzona 4981 (Magma HT Conditioner)

Problem: Over time the plinth surface had deteriorated due to constant contact with hot caustic.

Initial condition of plinth

Application of Belzona 4131

Application of Belzona 4181

Overcoated with 1391T

Application Situation
Plinth had deteriorated due to constant contact with hot caustic.
Application Method
Area cleaned with high pressure water to remove caustic residue.
4911 used as surface conditioner before application of 4131 which was used to rebuild profile of plinths.
4981 used as a conditioner before application of 4181 which will give resistance to caustic at elevated temperatures.
Belzona Facts
Customer needed the plinth rebuilt and needed a coating which would give resistance to caustic at elevated temperature.