Search Our Know-How in Action Case Studies

146 KHIAs found
BELZONA TUBE SHEET AND END COVER REPAIR
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The tube bundle and end cover of a heat exchanger at a local refinery was badly eroded.
BELZONA CHILLER
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1121 (Super XL Metal)

Belzona® 1341 (Supermetalglide)


Problem : Corrosion problems were beginning on the tube sheet and end covers.
BELZONA REVIVES 'MOTH-BALLED' POWER PLANT
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1121 (Super XL-Metal)

Belzona® 5811 (Immersion Grade)

Belzona® 2211 (MP Hi-Build Elastomer)


Problem : The power plant was sold under California's power industry de-regulation and was scheduled to be dismantled. The current energy crisis caused it to be...
BELZONA STANDS THE TEST OF TIME
Date Created: 11/23/2008
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Tube sheet was suffering from bi-metallic corrosion and channel box was suffering from erosion/corrosion.
BELZONA KEEPS THE SHOWERS HOT & CLEAN AT HOTEL
Date Created: 10/16/2009
Industry: Water / Wastewater (WATR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1511 (Super HT-Metal)

Belzona® 1391 (Ceramic HT Metal)


Problem : Breakdown of the original coating system had resulted in severe corrosion, deep pitting and through holes around the heating bundle. In addition the c...
BELZONA PROTECTS TUBE SHEET AND TUBES
Date Created: 4/1/2008
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1311 (Ceramic R-Metal), Belzona 1321 (Ceramic S-Metal), Belzona 1341 (Supermetalglide), Belzona 5811 (Immersion Grade)
Problem : Corrosion problems were beginning on the tube sheet and inlet tubes (75 mm).
FOUR LARGE CONDENSERS PROTECTED WITH BELZONA
Date Created: 10/13/2011
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1341 (Supermetalglide)

Belzona 5811 (Immersion Grade)


Problem : The client wanted to protect new tube sheets against bimetallic corrosion and tubes against corrosion/erosion. Also required to protect the condenser ...
BELZONA TAKES THE HEAT IN EXCHANGERS
Date Created: 5/16/2016
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT-Metal)

Belzona 1593


Problem : The brine heat exchangers operate at up to 138°C and are prone to rapid corrosion. The water box, separator channels and tube face had all suffered ex...
HEAT EXCHANGER RELIABLY REFURBISHED WITH BELZONA
Date Created: 5/18/2016
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT Metal)

Belzona 1391 (Ceramic HT)


Problem : This Propylene heat exchanger operates at up to 120°C and the tube face had suffered severe galvanic and pitting corrosion. The separator channels and...
Over 40 YEAR OLD CONDENSERS RESTORED WITH BELZONA
Date Created: 5/23/2007
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 1321 (Ceramic S-Metal), Belzona® 1311 (Ceramic R-Metal),
Problem : The leaks caused a rise in the condensate return water silicon content from 200 ppm to 4,600 ppm which in turn contaminates the boiler and contributes...
BELZONA RESTORES CORRODED COOLER COVER
Date Created: 11/22/2005
Industry: Marine (MRNE)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Both the inlet and outlet pipes on the cooler were totally corroded through with large holes in the body of the cover.
TWO DAY BELZONA REPAIR TO HEAT EXCHANGER
Date Created: 5/22/2007
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S Metal)


Problem : Heat exchanger was suffering bimetallic corrosion (copper tubes, steel tube sheet and cast iron covers), causing leakage on the tube sheet.
BELZONA EXTENDS CHILLER LIFE
Date Created: 8/1/2007
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Corrosion threatened the life of the chiller. With tight budgets the loss of a chiller would be unacceptable.
BELZONA RESTORES HEAT EXCHANGERS
Date Created: 3/15/2012
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S Metal)


Problem : Severe galvanic corrosion on the flange face and tube sheets of heat exchangers.
BELZONA REPAIRS LEAKING HEAT EXCHANGER TUBE SHEETS
Date Created: 2/11/2011
Industry: Marine (MRNE)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Severe erosion and galvanic corrosion between copper tubes and steel tube sheet.
BELZONA REPAIR AND PROTECTION OF REFRIGERATION UNIT
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Erosion-corrosion on all water side components. Particularly deep erosion on tube sheet around the tubes.
PROTECTION OF CHILLER WITH BELZONA CERAMIC METAL SYSTEM
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Corrosion of end covers, water box and tube sheet due to brackish water used for cooling.
BELZONA SEALS HOLED HEAT EXCHANGER
Date Created: 8/5/2005
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1591 (Ceramic XHT-Metal)


Problem : Hole in a tube sheet due to erosion and galvanic corrosion between copper tubes and steel tube sheet.
BELZONA SAVES OIL COOLER FROM SCRAP HEAP
Date Created: 8/19/2005
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : After 40 years in service the oil coolers were suffering from severe corrosion.
BELZONA REPAIRS CORRODED HEAT EXCHANGER FLANGE
Date Created: 8/29/2005
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The flange of the heat exchanger was corroded preventing correct sealing.
BELZONA RESTORES FRESH WATER COOLERS
Date Created: 9/26/2005
Industry: Marine (MRNE)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 5891 (HT Immersion Grade)

Belzona® 1111 (Super Metal)


Problem : Corrosion-erosion of inside vane, outside flanges and stud threads.
BELZONA TWO MAIN TURBINE COOLING WATER HEADS
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1341 (Supermetalglide)


Problem : As the headers feed water through main turbine cooling system, erosion/corrosion damage to divider plates and interior surface occurs.
BELZONA REPAIRS AND PROTECTS HEAT EXCHANGER
Date Created: 4/26/2016
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 4341 (Magma CR4)


Problem : Severe corrosion/erosion on both ends of two heat exchangers,
Health District HVAC Tube Sheet Repaired with Belzona
Date Created: 9/3/2018
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : THe tube sheet was severely corroded.
BELZONA REPAIRS OIL COOLERS
Date Created: 9/28/2013
Industry: Steel & Metal Processing (STEL)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R Metal)

Belzona 1391 (Ceramic HT)


Problem : Heat exchangers were suffering from electrochemical corrosion. Gaps occured between tube sheet and tubes and cooling water and oil started to mix.
BELZONA PROTECTS NEW CHILLER
Date Created: 3/20/2014
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : Due to the operational environment of the plant the Chiller was expected to suffer constant corrosion during operation if not protected. Based on th...
BELZONA REPAIRS AND PROTECTS 35 YEAR OLD CHILLER
Date Created: 4/20/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : Tube sheet was badly corroded and gas leaks were occurring.
BELZONA repairs and protects a heat exchanger against erosion/corrosion
Date Created: 7/9/2014
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1391 (Ceramic HT)


Problem : Problems due to high temperatures and erosion caused by particle flow
Belzona® Provides Corrosion Protection for Heat Exchanger Tube Sheets
Date Created: 3/31/2020
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 (Super-Metal)

Belzona 1391 (Ceramic-HT)


Problem : The tube sheet needs protection from high-temperature corrosion, chemical corrosion and bimetal corrosion to prevent further metal loss. Otherwise, it...
Nuclear HEX Refurbished with Belzona
Date Created: 10/30/2018
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT-Metal)

Belzona 1391T


Problem : River water used for the cooling system had cause corrosion and pitting on the tube sheet of a heat exchanger.
BELZONA RESTORES HEAT EXCHANGER
Date Created: 9/12/2011
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Galvanic corrosion on internal surfaces, particularly tube sheet and end covers.
BELZONA RESTORES TUBE SHEET PROTECTION
Date Created: 11/5/2012
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1321 (Ceramic S Metal)


Problem : Original coating on tube sheet had failed. Replacement required to prevent future corrosion.
BELZONA MATERIALS RECONDITION AIR CONDITIONER
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The tube sheet had suffered erosion/corrosion damage to the extent that three tubes no longer made contact with the sheet.
BELZONA® 1591 PROTECTS HEAT EXCHANGERS
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1591


Problem : Severe erosion-corrosion of the tube sheet and end cover caused by the hot Hydrocarbon mixture.
COOLING TOWER FAN BLADES REPAIRED WITH BELZONA
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1321 (Ceramic S-Metal)


Problem : Light damage and erosion on the leading edge of the blades reduces the overall efficiency and operation of the cooling system.
BELZONA REFURBISHES RAW JUICE HEATER
Industry: Sugar (SUGR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R- Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Erosion/corrosion of around tubes on tube sheet surface. Operation of heater proved ineffective and presented a safety hazard.
BELZONA CONCRETE COOLING TOWER BASINS
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 5811 (Immersion Grade)


Problem : Basins were deteriorated due to attack from chemically treated water. Left unchecked the concrete would continue to degrade and eventually result in l...
BELZONA REFURBISHMENT OF AFTERCOOLER HEADS
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)

Belzona® 9411 (Release Agent)


Problem : Years of erosion/corrosion had deteriorated the divider bars causing bypass and inefficiency.
BELZONA CHILLER PROTECTION
Date Created: 8/18/2005
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1341 (Supermetalglide)


Problem : Corrosion of the tube sheet and water box.
BELZONA CHILLS OUT BREWERY
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The tube sheet was badly eroded/corroded. There were numerous leaks between the tubes and the tube sheet.
BELZONA EMERGENCY LEAK SEALING
Date Created: 7/5/2005
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1321 (Ceramic S-Metal)


Problem : Bi-metallic corrosion between the tubes and the tube sheet had caused Freon leakage.
Know-How and Belzona® 4111 Make Critical Repair
Date Created: 5/9/2005
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 4111 (Magma-Quartz)


Problem : Lack of sufficient mixing of acid used for pH control in cooling tower water caused concrete deterioration on critical support members of cooling towe...
Belzona Protects Condenser Tube Sheet
Date Created: 6/13/2005
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1321 (Ceramic S-Metal)


Problem : Corrosion of the tube sheets of two condensers.
BELZONA SEALS HEAT EXCHANGER AT METHANOL PLANT
Date Created: 3/14/2011
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1511 (Super HT Metal)


Problem : There was a lot of leakage between tubes and sheet due to galvanic corrosion.
BELZONA PROTECTS HEAT EXCHANGER HEAD
Date Created: 10/2/2009
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1391 (Ceramic HT) 


Problem : Severe corrosion occurring due to source water. corrosion rate estimated at 0.05” (1.25mm) per year.
BELZONA PROTECTS HEAT EXCHANGER TUBE SHEETS
Date Created: 11/14/2009
Industry: Buildings & Structures (BSTR)  |  Application: CEP-Centrifugal Pumps (CEP)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Erosion corrosion protection required on tube sheets to prevent further loss of metal thacould otherwise lead to leakage, loss of efficiency and conta...
BAROMETRIC CONDENSER PROTECTED WITH BELZONA
Date Created: 12/4/2009
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1321 (Ceramic S-Metal)


Problem : Previous uncoated condenser was destroyed by erosion/corrosion.  A new condenser was manufactured and the decision made to protect it with Belzona.
BELZONA SEALS COOLER SHELL
Date Created: 4/13/2006
Industry: Military (MILI)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 1111 (Super Metal)
Problem : Erosion corrosion had caused hole in the shell of the cooler. Location and timescale made replacement impossible.
BELZONA REPAIRS HEAT EXCHANGER END COVERS
Date Created: 1/3/2006
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Holes and cracks had appeared on the end covers due to freezing water.
BELZONA WEATHERPROOFS INSULATED ROOFTOP DUCTING
Date Created: 6/29/2007
Industry: Buildings & Structures (BSTR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 5131 (EG Cladding)
Problem : Original protection no longer water-tight. Insulation was wet and water was leaking into the building. CUI was feared.
BELZONA REPAIRS SCHOOLS CHILLER
Date Created: 7/23/2007
Industry: Buildings & Structures (BSTR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Years of service had caused extensive corrosion on the chiller tube sheet face.
NEW TRANE CHILLER PROTECTED WITH BELZONA
Date Created: 12/29/2017
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1121

Belzona 1321


Problem : Customer had 3 large Trane chillers, about 30 years of age. Due to inefficiency of older models, the Customer is gradually replacing them with new mo...
New double Water box Traine chiller
Date Created: 3/1/2024
Industry: Buildings & Structures (BSTR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1121 (Super XL-Metal), Belzona 1321 (Ceramic S-Metal)
Problem : New chillers required protection before being put into service.
Belzona Protects Crude Oil HEX
Date Created: 5/6/2020
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1593


Problem : The Crude oil heat exchangers operate at up to 110°C and are prone to rapid corrosion. The separator channels and tube face can all suffer extreme cor...
BELZONA SAVES HEAT EXCHANGER FROM COSTLY REPLACEMENT
Date Created: 9/7/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : All ten heat exchangers had been replaced just one year ago. The covers were stainless steel but were welded with a carbon steel rod, setting up elect...
BELZONA REPAIRS TUBE SHEETS OF A HEAT EXCHANGER
Date Created: 9/7/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : One year old tube sheets were already leaking around the tubes. Electrolysis has eaten away much of the tube sheet and plate.
BELZONA SAVES REFINERY $50,000
Date Created: 3/7/2008
Industry: Fluid Flow (FLOW)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Galvanic corrosion and erosion resulting in loss of thickness and gasket sealing surfaces. This allows for working fluid to bypass portions of the mu...
BELZONA SAVES MONEY ON OIL-COOLER REPAIRS
Date Created: 12/15/2009
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1391 (Ceramic HT)


Problem : Due to the high temperature liquids, the sealing areas were eroded and corroded. Flanges, tubesheet and water box have been further damaged by corrosi...
BELZONA EXTENDS LIFE OF CHILLER
Date Created: 4/11/2008
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R Metal)

Belzona® 1321 (Ceramic S Metal)


Problem : Corrosion on tubesheets (4) from one of the chillers was noticed in 2005. Cooling water comes from a local lake which together with galvanic effects w...
VERY OLD BELZONA TUBE SHEET REPAIR
Date Created: 11/21/2008
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The tube sheet was suffering from bi-metallic corrosion and was in need of protection.
BELZONA REPAIRS AND REBUILDS POWER PLANT CONDENSER
Date Created: 2/5/2010
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal) 

Belzona® 1321 (Ceramic S Metal)


Problem : Inspection during the plant shutdown, showed severe corrosion on the heat exchanger with poor sealing on division bars and seal faces.
BELZONA PROTECTS NEW HEAT EXCHANGERS
Date Created: 8/25/2010
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 5891 (HT Immersion Grade)


Problem : These units required corrosion protection. They were designed to operate with sea water at 70°C.  
BELZONA EXTENDS THE LIFE OF HEAT EXCHANGER END COVERS
Date Created: 9/5/2011
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The heat exchanger unit end covers had become so badly eroded that they were potentially scrap.
BELZONA® 5811: EXCEEDING WHERE OTHERS FAIL
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 5811 (Immersion Grade)


Problem : Previous coatings had failed in a very short time. Loss of imitator coating and severe corrosion were causing the blockage of tubes, thus reducing eff...
Belzona: Stops Leaks in Cooling Towers
Date Created: 5/10/2005
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 2211 (MP Hi-Build Elastomer)

Belzona® 2221 (MP Fluid Elastomer)


Problem : Leaking water was causing economic concerns. The old joint sealants had worn down and ground movement caused leaks in the concrete floor and walls.
TYPICAL CHILLER REPAIR WITH BELZONA
Date Created: 11/22/2005
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 1311 (Ceramic R-Metal)
Belzona® 1321 (Ceramic S-Metal)
Problem : Corrosion of tube sheet and the end covers.
BELZONA® 5111 HAS EXCELLENT U.V. RESISTANCE
Industry: Pulp & Paper (PLPR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona® 5111 (Ceramic Cladding)


Problem : The structures were damaged from exposure to fumes and vapors inherent to the plant.
BELZONA PROTECTS EVAPORATOR TUBE SHEETS
Industry: Pulp & Paper (PLPR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1391


Problem : Erosion/corrosion of the tube sheet due to hot caustic (black liquor at 185ºF) and galvanic corrosion due to dissimilar metals.
BELZONA REPAIRS HYDROGEN COOLERS AND PIPING
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1121 (Super XL-Metal)

Belzona® 1341 (Supermetalglide)


Problem : Years of erosion-corrosion on uncoated turbine cooler parts forced this customer to seek a repair solution as opposed to the high costs associated wit...
BELZONA® 1391 PROTECTS JUICE HEATER END COVER
Industry: Sugar (SUGR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1391


Problem : Extensive corrosion pitting.
A COST EFFECTIVE SOLUTION TO SEVERE PITTING - 11 YEARS LATER: PERFECT
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Severe pitting at froth line top and side walls.
BELZONA® 1311 (CERAMIC R-METAL) SAVES A PLANT SIX WEEKS OF DOWNTIME
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R-Metal)


Problem : Small pin holes had developed in the heat exchanger plates
BELZONA ON EVAPORATOR TUBE SHEETS
Industry: Pulp & Paper (PLPR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1391


Problem : Erosion / corrosion of the tube sheet due to hot caustic black liquor at approximately 185ºF and galvanic corrosion between the stainless steel tubes ...
BELZONA SEALS JOINTS ON COOLING TOWER
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 3121 (MR7)

Belzona® 3921 (GSC Surface Conditioner)

Belzona® 9311 (Reinforcing Sheet)


Problem : Leaking joints prevented tower de-icing system to function properly, resulting in ice damage to concrete tower.
BELZONA® 1391 PROTECTS ABSORBER TOWER
Industry: General Industry (GIND)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona® 1391


Problem : MDEA is used at a temperature of 120°C (250°F) in this absorber and severe corrosion is experienced.
RESTORING AND COATING E5B HEAT EXCHANGER FACE
Date Created: 3/6/2024
Industry: Steel & Metal Processing (STEL)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1111 (Super Metal), Belzona 1321 (Ceramic S-Metal)
Problem : Galvanic corrosion on the tube face, caused by contact of 2 dissimilar metals.
BELZONA REBUILDS AND PROTECTS HEX END BELL AND CAP AT A BEVERAGE FACILITY
Date Created: 11/26/2018
Industry: Food & Drink (FOOD)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1391T 

Belzona 1511 (Super HT-Metal)


Problem : Erosion-corrosion wear caused by having no protective coating before the heat exchanger started its service life.
Belzona Internal Coating Protection for 3 Condensers and Absorbers
Date Created: 2/7/2019
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1391T

Belzona 9411 (Release Agent)


Problem : Tube sheets, water boxes and end covers were subject to high erosion-corrosion. As a result of galvanic corrosion and chemical attack, they were sever...
Graphite Heat Exchanger restored with Belzona
Date Created: 4/18/2019
Industry: Fluid Flow (FLOW)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1391T


Problem : The tube sheet and some of the tubes have been severely damaged due to a combination of chemical and erosive attack. The loss of material causes a red...
Heat Exchanger End Cover Repaired and Coated with Belzona
Date Created: 5/18/2021
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1221 (Super E-Metal)

Belzoan 9341 (Reinforcement Tape)

Belzona 1311 (Ceramic R-Metal)

Belzona 1341 (Supermetalglide)


Problem : Seawater had severely corroded this end cover causing very thin wall conditions leading to holing. Holes were more pronounced after grit blasting. The...
Repair and Protection of Inter Stage Chiller Tubesheet
Date Created: 12/31/2023
Industry: Mining & Quarrying (MINQ)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1311 (Ceramic R-Metal), Belzona 1392 (Ceramic HT2)
Problem : Tubesheet suffering from galvanic corrosion. Erosive damage at the division bar was observed; severe erosion due to the slurry medium.
Belzona Refurbishes a heat exchanger in the Sugar Industry
Date Created: 9/14/2022
Industry: Sugar (SUGR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT Metal)

Belzona 1391S 


Problem : The head plate of the heat exchanger was very badly corroded and wad already showing in part considerable loss of wall thickness.
BELZONA SOLUTIONS FOR REBUILDING & COATING LUBE COOLER/END COVER
Date Created: 7/18/2025
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1311 (Ceramic R-Metal), Belzona 1391 (Ceramic HT), Belzona 9111 (Cleaner Degreaser)
Problem : One of our offshore clients reported a case of corrosion affecting their heat exchanger (HEX) equipment. The root cause was identified as prolonged ex...
BELZONA KEEPS AIRPORT COOL WITH HEAT EXCHANGER REPAIR
Date Created: 9/15/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1321 (Ceramic S-Metal)


Problem : Corrosion caused by the chemicals in the system were eating away the tube sheet and end cover.
BELZONA REPAIRS AND PROTECTS HEAT EXCHANGER FROM CORROSION
Date Created: 9/17/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : Pitting corrosion and bi-metallic corrosion caused leakage.
BELZONA REFURBISHES HEAT EXCHANGER ON CRUISE LINER
Date Created: 11/20/2012
Industry: Marine (MRNE)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1121 (Super XL-Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The heat exchanger tube sheet was found to be corroded, with isolated pitting in the division bar seal face.
CONDENSER TUBESHEET RESTORED WITH BELZONA
Date Created: 2/20/2014
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1331

Belzona 2211 (MP Hi-Build Elastomer)


Problem : The tubesheet had suffered from bimetallic corrosion around the tubes and at the edges of the tubesheet as well as metal loss due to erosion.
Belzona repairs leaky pipes from a heat exchanger
Date Created: 9/27/2018
Industry: (LOMU)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 9111 (Cleaner Degreaser) Belzona 1111 (Super Metal) Belzona 5892


Problem : Sealing problem between the tubes and the tubular sheet on these heat exchangers due to a bad tube expansion, 50% of the tubes were leaking.
RECOVERY AND PROTECTION OF OLD HEAT EXCHANGER WITH BELZONA
Date Created: 1/29/2016
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1391T 

Belzona 9411 (Release Agent)


Problem : Surface of the tube sheets were badly corroded and required recovery and protection to stop unwanted leakages.
MARINE CHILLER UNITS MADE SHIP SHAPE WITH BELZONA
Date Created: 3/30/2017
Industry: Marine (MRNE)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1212

Belzona® 1321 (Ceramic S-Metal)


Problem : These aluminium chiller units had suffered severe pitting and metal loss caused by microbial attack and bi-metallic corrosion. The newly commissioned ...
REPAIRING COOLING TOWER SEAMS WITH BELZONA
Date Created: 9/11/2015
Industry: Buildings & Structures (BSTR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 2911 (Elastomer QD Conditioner)

Belzona 9341 (Reinforcement Tape)

Belzona 2131 (D & A Fluid Elastomer)


Problem : Towers were leaking around seams and protrusions.
BELZONA REPAIR TO OIL COOLER
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : The unit was severely damaged and leaking as a result of bimetallic corrosion.
BELZONA REPAIRS AND PROTECTS CORRODED SHELL
Date Created: 7/5/2005
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® Marine Metal

Belzona® 1321 (Ceramic S-Metal)


Problem : Shell and dished end were highly corroded due to chemical attack that resulted in critical wall thickness reduction in the shell.
BELZONA RESTORES CORRODED HEAT EXCHANGER
Date Created: 11/5/2012
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1311 (Ceramic R Metal)

Belzona® 1341 (Supermetalglide)


Problem : The tube sheet was badly corroded. Particularly deep erosion on tube sheet around the tubes.
BELZONA SOLUTION FOR REBUILDING AND COATING OF CHILLERS - 1M DIAMETER
Date Created: 5/15/2025
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1121 (Super XL-Metal), Belzona 5821
Problem : The tube sheet and end cover of the chiller units experienced severe corrosion, resulting in a significant decline in efficiency. Additionally, the we...
BELZONA SOLUTIONS FOR REBUILDING AND COATING OF TUBE SHEET AND END COVER OF THE HEAT EXCHANGER
Date Created: 5/16/2025
Industry: Water / Wastewater (WATR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1111 (Super Metal), Belzona 5892
Problem : The heat exchanger tube sheet and cover suffered from metal loss and severe pitting as a result of erosion and corrosion. The customer sought a soluti...
Belzona Repairs and Protects 18 Chillers
Date Created: 5/6/2020
Industry: ()  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 SuperMetal Belzona 5811 Immersion Grade


Problem : Tubesheet and water box surfaces of 10 Chillers of a Plastic Plant's HVAC system were corroded over time. The client had purchased 8 new chillers for ...
Linde Intercooler Repair
Date Created: 1/31/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1111 (Super Metal), Belzona 1321 (Ceramic S-Metal)
Problem : Intercooler tube sheet and end covers had corrosion due to b-metallic corrosion.
Belzona Saves Chiller Head
Date Created: 4/1/2024
Industry: Commercial Facilities (COMM)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1111 (Super Metal), Belzona 1321 (Ceramic S-Metal)
Problem : Chiller head was suffering from severe corrosion/chemical attack due poor water treatment.
Offshore Heat Exchanger Maintenance with Belzona.
Date Created: 8/25/2021
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 Super HT Metal

Belzona 1391S

Belzona 1391 Ceramic HT


Problem : Existing titanium bushings had caused severe bimetallic corrosion on the carbon steel endplate surfaces. The titanium bushing endplate surfaces was in...
BELZONA SEALS AIR COOLER COVER
Date Created: 10/20/2020
Industry: Marine (MRNE)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 2911 (QD Conditioner)

Belzona 2211 (MP Hi-Build Elastomer)


Problem : Due to the design of the Air Cooler, the gasket under the cover could not be changed. Over time and vibrations of Cooler, the deformed gasket lost its...
Belzona 1593 special internal coating
Date Created: 10/21/2020
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1593


Problem : Chemical attack (corrosion) was only one problem, another problem was that coating area was not easy available.
Belzona protects a Heat Exchanger in a CHP Plant
Date Created: 5/12/2021
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1121 (SUPER XL-METAL)

Belzona 5811 (Immersion Grade)


Problem : The problem was erosion and corrosion of the tube sheets and capacitor chambers. Erosion occurred as a result of liquid flow, galvanic corrosion occur...
BELZONA RECONSTRUCTS THE COVER AND FLANGE OF A HEAT EXCHANGER
Date Created: 4/4/2019
Industry: ()  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 (Super-Metal)


Problem : The flange and the cover of this exchanger were badly damaged by corrosion and needed to be rebuilt.
END COVER OF CONDENSER RECEIVES BELZONA HT SOLUTION
Date Created: 8/19/2015
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT-Metal)

Belzona 1591 (Ceramic XHT)


Problem : Severe pitting corrosion appeared on the cover after years of operation. The worst pitting is about 10mm deep.
BELZONA REPAIRS HOLE ON SCUM TANK
Date Created: 8/21/2015
Industry: Water / Wastewater (WATR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1161 (Super UW-Metal)

Belzona 9111 (Cleaner Degreaser)


Problem : Hole caused by corrosion.
BELZONA REPLACES EXPANSION JOINTS IN OLYMPIC SIZED LAP POOL
Date Created: 8/8/2016
Industry: Buildings & Structures (BSTR)  |  Products:

Belzona 2211 (MP Hi-Buid Elastomer)

Belzona 2221 (MP Fluid Elastomer) 


Problem : Despite formulation improvements in the concrete manufacturing process, the final product is still susceptible to all forms of chemical attack.
Belzona Protects a New Condenser
Date Created: 10/18/2017
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 5892


Problem : The coating was required to offer protection against attack from aqueous solutions at elevated temperature.
BELZONA HANDLES STRESS CRACK CORROSION AT A JUICING PLANT
Date Created: 12/20/2017
Industry: Food & Drink (FOOD)  |  Products:

Belzona 1391T

Belzona 1511 (Super HT-Metal)

Belzona 9341 (Reinforcement Sheet) 


Problem : Stress crack corrosion leaking hot water out of the pasteurization pipes onto other pipes and machinery.
OIL COOLERS PROTECTED WITH BELZONA
Date Created: 3/21/2016
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : The customer was getting cross contamination between process cooling water and process lubricating oil, due to the corrosion at the copper tube and ca...
CONDENSER REPAIRED WITH BELZONA
Date Created: 7/4/2014
Industry: Steel & Metal Processing (STEL)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1321 (Ceramic S-Metal)

Belzona 9111 (Cleaner/Degreaser)


Problem : Machine was in service for a long time, which resulted in unacceptable tube sheet wear (thinning, in some places up to 5-7 mm from the original thickn...
BELZONA PROVEN SOLUTION FOR CONDENSER MAINTENANCE
Date Created: 1/11/2013
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 2141 (ACR-Fluid Elastomer) 

Belzona® 1161 (Super UW-Metal)

Belzona® 5831 (ST-Barrier)


Problem : Replacing and welding new parts was not an option as hot work could cause potential stress damage to the condenser and would damage the newly installe...
BELZONA PROTECTS AIR DIFFUSER AGAINST CORROSION
Date Created: 9/17/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 3211 (Lagseal)


Problem : The sheet metal on the air diffuser was suffering from corrosion.
BELZONA REBUILDS ERODED TUBE SHEET BASE
Date Created: 9/16/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1391 (Ceramic HT)


Problem : The molten slag is dripped into water spray which cools it to form granules much like grains of sand. The slag is removed and the water is then cooled...
BELZONA PROTECTS POWER PLANT CONDENSERS
Date Created: 9/11/2014
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1321 (Ceramic S-Metal)

Belzona® 1341 (Supermetalglide)


Problem : Corrosion/erosion on the turbine condensers (heat exchangers) after years of operation. Originally un-lined, extensive bimetallic corrosion had occurr...
BELZONA PROTECTS CHILLER TUBE SHEET
Date Created: 9/5/2014
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1321 (Ceramic S-Metal)

Belzona 9111 (Cleaner/Degreaser)


Problem : The chiller tube sheet was suffering from corrosion due to bi-metallic corrosion.
IMMACULATE BELZONA HEAT EXCHANGER REPAIR
Date Created: 9/9/2011
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1391 (Ceramic HT)


Problem : Surface of the tubesheet was badly corroded and required protection before leakage became an issue.
FOUR BELZONA REPAIRED CONDENSERS STILL IN SERVICE AFTER 17 YEARS
Date Created: 4/11/2011
Industry: Buildings & Structures (BSTR)  |  Application: CEP-Centrifugal Pumps (CEP)  |  Products:

Belzona® 1311 (Ceramic R Metal)

Belzona® 1321 (Ceramic S Metal)


Problem : Corrosion pitting had occurred around the tubes as a result of bi-metallic corrosion effects and the chloride content of the used river water.
BELZONA PROTECTS NEW HEAT EXCHANGER
Date Created: 7/12/2010
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1321 (Ceramic S Metal)


Problem : Protection against anticipated corrosion on new heat exchanger.
BELZONA STOPS LEAK DRAIN PIPE AND HOT WELL PUMP
Date Created: 7/27/2010
Industry: Water / Wastewater (WATR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1161 (Super UW Metal)

Belzona 1291 (ES-Metal)

Belzona 9341 (Reinforcing Tape)


Problem : Leaking drain pipe and hot well pump at Water Treatment Plant
BELZONA FACTORY APPLIED TO CHILLER
Date Created: 12/28/2009
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S-Metal)


Problem : Chillers suffer constant corrosion due to water treatment chemicals. In order to protect their costly investment this customer chose to pro-actively p...
4000 TON CHILLER TUBE SHEET PROTECTED WITH BELZONA
Date Created: 3/27/2008
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 1121 (Super XL Metal)
Belzona® 1321 (Ceramic S Metal)

Problem : Eroded 72" dia tube sheet faces with leaks between the tubes & the tube sheet
BELZONA SEALS CONDENSER EXPANSION JOINT
Date Created: 8/1/2007
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 2121 (D&A Hi-Coat Elastomer)

Belzona® 2911 (Elastomer QD Conditioner)


Problem : The efficiency of the unit was low because of the leaks in the expansion joint.
NO FLOOR? NO PROBLEM FOR BELZONA
Date Created: 12/1/2008
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:
Belzona® 1121 (Super XL Metal)
Belzona® 5811 (Immersion Grade)
Belzona® 3121 (MR-7)

Problem : Floor was corroded badly and needed replacing during an outage.
BELZONA SEALS CONCRETE COOLING TOWER BASINS
Date Created: 12/18/2008
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:
Belzona® 4111 (Magma Quartz)
Belzona® 5811 (Immersion Grade)

Problem : Cracks in the concrete were allowing water leaks into the environment.
BELZONA SEALS JOINTS IN UNDERGROUND PIPELINE
Date Created: 12/20/2008
Industry: Buildings & Structures (BSTR)  |  Application: CEP-Centrifugal Pumps (CEP)  |  Products:

Belzona® 4111 (Magma Quartz)

Belzona® 2211 (MP Hi Build Elastomer)


Problem : Power Plant was losing the cooling water through the expansion joints at the concrete pipe junctions.
BELZONA REBUILT HEAT EXCHANGER COVER
Date Created: 7/7/2009
Industry: Marine (MRNE)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1111 (Super Metal)


Problem : Damage on the original profile of the cooler top-cover due to erosion/corrosion, led to leaks and loss of efficiency.
BELZONA REPAIRS AND PROTECTS 18 FOOT DIAMETER FLANGE FACE
Date Created: 9/29/2009
Industry: General Industry (GIND)  |  Application: GSS-Gaskets, Seals and Shims (GSS)  |  Products:

Belzona® 1111 (Super Metal)

Belzona® 4341 (Magma CR4)


Problem : Flange was attacked by 98% Sulfuric acid at elevated temperature after Teflon lining was damaged.
BELZONA SAVES VITAL CHILLER
Date Created: 7/31/2007
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 1311 (Ceramic R-Metal)
Belzona® 1321 (Ceramic S-Metal)
Problem : Bi-metallic corrosion was deteriorating the tube sheet surfaces. If the problem was left unresolved, the chiller would eventually suffer servere damag...
BELZONA COATED CHILLERS 10 YEARS ON
Date Created: 6/4/2007
Industry: General Industry (GIND)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 1321 (Ceramic S-Metal)
Problem : Premature corrosion was taking place and long term protection was needed.
COOLING TOWER COATED WITH BELZONA® 5811 BY SPRAY
Date Created: 3/19/2006
Industry: Buildings & Structures (BSTR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona® 5811 (Immersion Grade)
Problem : Previous coating was coming off before going into service.
BELZONA RESTORES FOUR CONDENSER TUBE SHEETS IN FIVE DAYS
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1121 (Super XL-Metal)

Belzona® 1341 (Supermetalglide)


Problem : Insertion of new stainless steel sleeves caused ligament damage to the inlet tube sheets resulting in severe tube to tube sheet leaks and a forced out...
BELZONA REPAIRS TO RUBBER LINED CONDENSER
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 2211 (MP Hi-Build Elastomer)


Problem : Spark testing of rubber lining highlighted several defects requiring repair.
BELZONA HOT GROUNDWATER PROTECTION
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona® 1591


Problem : Hot groundwater contains high levels of minerals, sulfer and abrasives. There is erosion/corrosion of the tube sheet face at elevated temperature.
Corrosion Prevention in Condenser Exchanger with Belzona 1321
Date Created: 2/5/2025
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1321 (Ceramic S-Metal), Belzona 9111 (Cleaner Degreaser)
Problem : Corrosion between the surface and tubes due to water flow in the condenser exchanger
Brine Heat Exchanger Cover Refurbishment
Date Created: 1/20/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1593, Belzona 9111 (Cleaner Degreaser), Belzona 9411 (Release Agent)
Problem : The water box cover had suffered severe pitting corrosion and the separator channel and edges needed to be rebuilt to prevent bypass of the separator ...
Brine Heat Exchanger Tube Face Refurbishment
Date Created: 1/20/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1593, Belzona 9111 (Cleaner Degreaser), Belzona 9411 (Release Agent)
Problem : The tube face had suffered severe galvanic and pitting corrosion and the separator channels and tube face needed to be rebuilt to prevent bypass of th...
Brine Heat Exchanger Water Box Refurbishment
Date Created: 1/20/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1593, Belzona 9111 (Cleaner Degreaser)
Problem : The water box had suffered pitting corrosion and needed resurfacing. In addition, the client required a lining to prevent further attack to the tube f...
Belzona Restores HEX Tube Sheet to Prevent Leak
Date Created: 12/10/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1391T, Belzona 1511 (Super HT-Metal), Belzona 9111 (Cleaner Degreaser)
Problem : The customer has a boiler that is used to heat up fluid at their site for their process. The asset is over 20 years old and the tube sheet has eroded ...
Belzona repairs 6 heat exchangers
Date Created: 3/21/2019
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT Metal)

Belzona 1391T


Problem : 12 tube sheets suffering from corrosion and chemical attack were exposed to elevated temperatures (up to 200°C - Dry Heat) when in service, therefore ...
Belzona apply Internal Lining to Heat Exchanger Shell
Date Created: 1/17/2020
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT-Metal)

Belzona 1593


Problem : Internal corrosion to the internals of a heat exchanger
Tube sheet engine cooling exchanger protection with Belzona
Date Created: 6/1/2020
Industry: Power (POWR)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1111 (super metal)

Belzona 4311 (Magma CR1)


Problem : These strong acids even if they are diluted cause big corrosion.
BELZONA WORKS WHEN THE HEAT IS ON
Date Created: 9/23/2014
Industry: Steel & Metal Processing (STEL)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1251 (HA-Metal)


Problem : Leaks had formed around a set of plates used to support cooling coils where they pass through the wall of the roaster. 
BELZONA OFFERS PROTECTION TO NEW FLOATING HEAD
Date Created: 9/14/2015
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1321 (Ceramic S-Metal)


Problem : Deterioration of the surface due to erosion/corrosion by in-service conditions.
Cooling Water Head Brought Back To Life With Belzona 1391T
Date Created: 11/19/2024
Industry: Oil & Gas (OILG)  |  Application: HEX-Heat Exchangers (HEX)  |  Products: Belzona 1111 (Super Metal), Belzona 1391T
Problem : Customer pulled several HEX for routine inspections and discovered bad pitting on one the Cooling Water Heads. They were in a small Pit-Stop and had 3...
Dyno Mill Wear Ring Repair
Date Created: 8/6/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: FBC-Fans, Blowers and Compressors (FBC)  |  Products: Belzona 1311 (Ceramic R-Metal), Belzona 1812 (Ceramic Carbide FP), Belzona 9811
Problem : The internal diameter of a 40” Dyno Mill wear ring exhibited significant wear and erosion in multiple sections. The high abrasion environment within t...