Sewage plant leaking pipe
Date Created: 11/27/2024
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1161 (Super UW-Metal), Belzona 5892 Problem : The inner material of the pipe has degraded because wastewater is corrosive. They attempted to stop the leak caused by the metal loss by conventionall... |
||
BELZONA PROTECTS A STAINLESS STEEL WATER PIPE
Date Created: 11/10/2017
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1151 (Smoothing Metal) Belzona 4311 (Magma CR1) Problem : The bleach solution dripped onto the stainless steel pipes over time, causing corrosion and pitting damage. Further damage to the stainless steel pip... |
||
BELZONA 5812DW RESTORES POTABLE WATER TANK
Date Created: 7/29/2016
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5812DW Belzona 1111 (Super Metal) Belzona 9341 (Reinforcement Tape) Problem : This rural water utility's 40-year-old primary storage tank for potable water had corrosion, pitting, sediment build-up, and a few dime-sized holes. A... |
||
Belzona 1321 Investment Coating for Pump Preservation
Date Created: 2/10/2023
Industry: Water / Wastewater (WATR) | Application: ENC-Engines and Casings (ENC) | Products: Belzona 1321 (Ceramic S-Metal) Problem : New customer receives pumps from many different industries across the region and are posed with the task of either replacing or offering a repair/main... |
||
Refurbishment of Drinking Water Split Casing Pump
Date Created: 10/22/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal), Belzona 1341N (Supermetalglide) Problem : Customer faced corrosion and erosion in the casing of drinking water pump and it was unusable before Belzona repair. |
||
Repeated Coating of Split Casing Pump for Drinking Water
Date Created: 10/22/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal), Belzona 1341N (Supermetalglide) Problem : The pump owner was faced with the problem of erosion-corrosion inside the pump, causing pitted areas in the internal surface every two years. To solve... |
||
Belzona restores Concrete Water Reservoir
Date Created: 9/10/2024
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4111 (Magma-Quartz), Belzona 5812 DW Problem : Local authorities water reservoir was leaking. Divers had entered the tank and not found the source of the leak. |
||
7 Pumps For Belzona
Date Created: 10/18/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1341 (Supermetalglide) Problem : Customer had 7 pumps that were 1 year old that had heavily corroded due to no coating. They bought 7 new pumps and decided to protect their investment... |
||
Belzona Seals The Check Valves
Date Created: 7/8/2024
Industry: Water / Wastewater (WATR) | Application: GSS-Gaskets, Seals and Shims (GSS) | Products: Belzona 2111 (D & A Hi-Build Elastomer), Belzona 2911 (Elastomer QD Conditioner), Belzona 9411 (Release Agent) Problem : These irrigation check valve gaskets wear out and factory provided replacement gaskets don't last through one season. |
||
BELZONA 1212 SEALS A LEAK ON A WASTEWATER HOLDING TANK
Date Created: 9/16/2018
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1212 Problem : When the pipes were installed through the concrete wall, a grout was used to seal the area around the pipe. After many years of use, the grout began t... |
||
BELZONA PROVIDES THE SOLUTION TO A PUMP PROBLEM
Date Created: 5/4/2016
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal) Belzona 1321 (Ceramic S-Metal) Problem : The pump had a 1/4" hole appear on the outside of the volute, allowing for wastewater to leak during operation. After opening the pump, it was discove... |
||
Belzona Protects Against Impeller Wear
Date Created: 7/4/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R-Metal), Belzona 1321 (Ceramic S-Metal) Problem : This wastewater impeller was suffering from abrasive wear. |
||
Belzona 1212 for Emergency pump repair
Date Created: 5/4/2021
Industry: Water / Wastewater (WATR) | Application: PDP-Positive Displacement Pumps (PDP) | Products: Belzona 1212 Problem : A faulty section of weld on the lower side of the pump was leaking raw sewage. |
||
Belzona protects Wastewater expansion bellows.
Date Created: 5/4/2021
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 2911 QD Conditioner Belzona 9341 Reinforcement Sheet Belzona 2221 MP Fluid Elastomer Problem : These rubber wastewater expansion bellows were being weathered by UV and exposure resulting in cracking. |
||
Belzona 1212 Repairs a Worn Wastewater Lift Station Pump
Date Created: 10/15/2018
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1212 Problem : There was a hole worn underneath the impeller on the volute from "rags" in the wastewater system getting caught. This allowed for raw wastewater to le... |
||
BELZONA PROTECTS THE DRINKING WATER
Date Created: 11/4/2014
Industry: Water / Wastewater (WATR) | Products: Belzona 5811DW2 (DW Immersion Grade) Problem : The pump assembly was heavily corroded and the 40 year old pipe was corroded bad enough that it had to be replaced. |
||
Wastewater Pump Impeller
Date Created: 12/27/2022
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 Supermetal Belzona 1321 S-Metal Problem : Pump Impeller was pitted and damaged, and missing chunks out of a few of the veins, and they were wore down on the ends. We needed to build up the ve... |
||
Belzona materials repair, protect and improve severally damaged diffuser for pump station
Date Created: 8/27/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal), Belzona 1982 (SuperWrap II), Belzona 2141 (ACR-Fluid Elastomer), Belzona 2941 (Elastomer SP-Conditioner), Accessories Problem : Following the decision to rebuild a pump station for mechanical wear issues, it was unexpectedly discovered that there was severe cavitation damage ha... |
||
Belzona Repairs Damaged Drum Filter to Keep Wastewater Plant Running
Date Created: 9/29/2018
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1221 (Super E-Metal) Belzona 2911 (Elastomer QD Conditioner) Belzona 2121 (D&A Hi-Coat Elastomer) Problem : The drum itself was damaged, possibly during shipping or installation, as it was a new unit. The track where the drum turned was dented and this caus... |
||
Concrete Repair in Wastwater Clarifier
Date Created: 6/25/2024
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4131 (Magma-Screed), Belzona 4911 (Magma TX Conditioner) Problem : The Clarifier was suffering from damage to the concrete due to the age of the Clarifier and constant water and chemicals. Instead of replacing they ch... |
||
BELZONA REPAIRS AND SAVES INTERNALS OF WASTEWATER PIPE
Date Created: 3/23/2016
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1121 (Super XL-Metal) Belzona 5811 (Immersion Grade) Problem : The pipe was corroded so badly that the pitting was causing pin holes in the substrate. |
||
Belzona Stops Clarifier Leak Externally
Date Created: 9/26/2014
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1291 (ES-Metal) Belzona 1161 (Super UW-Metal) Belzona 9341 Problem : The leak was causing an environmental hazard as well as slippery walkways for pedestrians. The customer could not drain the unit. An external repair w... |
||
BELZONA ALLOWS HOUSTON CLARIFIER TO BE CLEAR AGAIN
Date Created: 9/17/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4131 (Magma-Screed) Belzona 5811 (Immersion Grade) Problem : With damaged concrete and no coating, the trough was hard to keep clean, taking 2-3 times longer than when new. |
||
Repair and Protection of Damaged Tubesheet of Air-Water Heat Exchanger
Date Created: 11/27/2023
Industry: Water / Wastewater (WATR) | Application: HEX-Heat Exchangers (HEX) | Products: Belzona 1111 (Super Metal), Belzona 5892 Problem : Corrosion and erosion of the tubesheet due to the leaks caused by improper tube expansion. |
||
Belzona Rebuilds and Protects a Clarifier
Date Created: 11/29/2018
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4111 (Magma-Quartz) Belzona 5811 (Immersion Grade) Belzona 5111 (Ceramic Cladding) Problem : The concrete roller track of this clarifier became damaged during operation and needed to be rebuilt. The floats and turbines had begun to corrode, so... |
||
Belzona repairs the suction part of a hydro turbine
Date Created: 1/22/2019
Industry: Water / Wastewater (WATR) | Application: ENC-Engines and Casings (ENC) | Products: Belzona 1311 (Ceramic R-Metal) Belzona 1331 Belzona SuperWrap II Problem : The internal surface of this hydro turbine presented an important loss of metal which ultimately led to a hole. |
||
Axial Flow Pump Coating with Belzona
Date Created: 1/5/2021
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R Metal) Belzona 1341 (Supermetalglide) Problem : The diffuser vanes of the pump has suffered extensive damage from erosion. Due to the age of the pump spare parts were not available & a replacement d... |
||
Belzona Rebuilds Grundfos Pump Impeller for the Wastewater Industry
Date Created: 6/1/2022
Industry: Water / Wastewater (WATR) | Products: Belzona 1311 (Ceramic R-Metal) Belzona 1812 (Ceramic Carbide FP) Belzona 1321 (Ceramic S-Metal) Problem : A Grundfos pump impeller had been severely damaged during normal service by erosion and corrosion. |
||
BELZONA PROTECTS WATER TREATMENT PLANT FILTER
Date Created: 8/25/2010
Industry: Water / Wastewater (WATR) | Application: WPA-Wall Problem Areas (WPA) | Products: Belzona® 1121 (Super XL Metal) Belzona® 4311 (Magma CR1) Problem : Severe corrosion of the stainless steel substrate due to the presence of Hydrogen Sulphide and Sulphuric acid. These are created by bacterial action i... |
||
Belzona Repairs Cavitation Damage on Potable Water Pump.
Date Created: 3/29/2009
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Belzona® 1221 (Super E Metal) Belzona® 1341 (Supermetalglide) Problem : Suction bowl badly damaged by cavitation. |
||
CAVITATION DAMAGED IMPELLER REPAIRED WITH BELZONA
Date Created: 3/30/2009
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1221 (Super E Metal) Belzona® 1341N (Supermetalglide). Problem : Impeller was damaged by cavitation leading to vibration in the pump. NSF approved products required. |
||
CAVITATED PUMP DIFFUSER RESTORED WITH BELZONA
Date Created: 3/30/2009
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Problem : Cavitation had caused severe metal loss to pump impeller and diffuser. New impeller was available but no diffuser available. |
||
STORM WATER PUMP PROTECTED WITH BELZONA FOR 10 YEARS
Date Created: 3/30/2009
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1321 (Ceramic S-Metal) Belzona® 5811 (Immersion Grade) Problem : Original pump deteriorated due to erosion corrosion. City decided to protect suction bell and diffuser with Belzona coatings before placing into servi... |
||
BELZONA PROVIDES LONG TERM REPAIRS TO CLARIFIER
Date Created: 3/30/2009
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 4141 (Magma Build) Belzona® 4111 (Magma Quartz) Problem : Severe cracks appearing in concrete walls and spalling concrete over re-bar on columns. |
||
Belzona protects clarifier track
Date Created: 10/26/2021
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4911 Belzona 4111 (Magma-Quartz) Problem : The damage on the track on the clarifier needed to be rebuilt to a smooth surface in order to allow the operation of the 'crane' unit. |
||
Belzona protects pumps for water treatment plant
Date Created: 10/28/2021
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1331 Problem : Pump linings suffer from erosion and corrosion over time due to exposure to the process stream. A lining resistant to erosion was required |
||
PELTON TURBINE NOZZLE HEAD
Date Created: 2/9/2023
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1341 (Supermetalglide), Belzona 2141 (ACR-Fluid Elastomer), Belzona 2941 (Elastomer SP-Conditioner) Problem : Cavitation damage on the substrate due due to high pressure on the nozzle head |
||
1000/700 ALLEN GWYNNE PUMP PROTECTED WITH BELZONA
Date Created: 7/25/2006
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1341 (Supermetalglide) Problem : Pump required coating to reduce corrosion and improve efficiency. |
||
BELZONA SPECIFIED TO OEM
Date Created: 12/1/2008
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1341 (Supermetalglide) Problem : Plant had previous experience of Belzona increasing efficiency and wanted new pumps coating before delivery |
||
BELZONA SEALS HOLES IN SPRINKLER TANK
Date Created: 12/3/2007
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 1111 (Super Metal) Problem : The tank was suffering from corrosion which had affected the wall thickness of the tank. In several areas this had caused holes in the tank which were... |
||
BELZONA PROTECTS WASTEWATER PUMP FROM EROSION-CORROSION
Date Created: 9/15/2013
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1321 (Ceramic S-Metal) Problem : High levels of erosion-corrosion caused by entrained solids in wastewater media being pumped for processing. |
||
BELZONA PROTECTS A NEW WASTE WATER PUMP AND IMPELLER FROM EROSION
Date Created: 8/10/2016
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1331 Problem : Previous supplied pumps had not met the customers expectations of longevity due to the impeller and volute being worn away by the erosion caused by wa... |
||
WASTEWATER VACUUM TRUCK INTERNAL COATING AND REPAIR
Date Created: 12/12/2016
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5811 (Immersion Grade) Belzona 1321 (Ceramic S-Metal) Belzona 1812 (Ceramic Carbide FP)
Problem : This damage was leading to failures within the intake pipe and corrosion was being found throughout the tank as a whole. If not addressed properly ... |
||
BELZONA KEEPS THE SHOWERS HOT & CLEAN AT HOTEL
Date Created: 10/16/2009
Industry: Water / Wastewater (WATR) | Application: HEX-Heat Exchangers (HEX) | Products: Belzona® 1511 (Super HT-Metal) Belzona® 1391 (Ceramic HT Metal) Problem : Breakdown of the original coating system had resulted in severe corrosion, deep pitting and through holes around the heating bundle. In addition the c... |
||
BELZONA LOBE REPAIRS AVOID DELAYS
Date Created: 9/12/2011
Industry: Water / Wastewater (WATR) | Application: PDP-Positive Displacement Pumps (PDP) | Products: Belzona® 2131 (D&A Fluid Elastomer) Problem : the rubber lobes wear but there is a delay of 4-6 weeks for the delivery of these lobes. |
||
LONGEVITY PUMP REPAIR WITH BELZONA
Date Created: 7/26/2011
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1391 (Ceramic HT) Problem : The pumps suffered from severe erosion/corrosion as they transport hot water at temperatures of 90-100 °C. |
||
BELZONA® 1341 IMPROVES SWIMMING POOL PUMP PERFORMANCE
Date Created: 8/4/2011
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R Metal) Belzona® 1341 (Supermetalglide) Problem : Erosion corrosion, aggravated by galvanic corrosion and corrosion from pool chemicals had reduced pump performance. |
||
BELZONA REPAIRS AN UNDERGROUND SEWAGE PLANT
Date Created: 7/26/2011
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5811 (Immersion Grade) Problem : Prior to the application of a Belzona coating, it is required that new concrete should be allowed to cure for 28 days or until the moisture content ha... |
||
BELZONA REPAIRS DAMAGED WASTEWATER PUMP
Date Created: 7/21/2014
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R-Metal) Belzona 1321 (Ceramic S-Metal) Problem : Erosion from solid material in process fluid had destroyed impellor and holed casing of a wastewater pump. |
||
WATER PUMPS REPAIRED AT HISTORIC RESERVOIR
Date Created: 9/22/2014
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal) Belzona 1341 (Supermetalglide) Problem : After years of frequent use, certain areas of the pumping equipment were suffering from cavitation damage, which in turn was seriously hindering the e... |
||
BELZONA PROTECTS IRRIGATION CULVERT
Date Created: 9/26/2007
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona® 5811 (Immersion Grade) Belzona® 9331 (Reinforcing sheet) Problem : Debris, sand, and silt carried by irrigation water wore through the galvanizing in one season. Left uncorrected, the underlying carbon steel pipe wou... |
||
BELZONA® 1341 STANDS THE TEST OF TIME AT IRRIGATION PLANT
Date Created: 11/24/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1341 (Supermetalglide) Problem : Due to general erosion/corrosion to this impellor, the customer requested sacrificial coating to protect the equipment. |
||
Belzona Saves the Alignment of the Pump and Motor
Date Created: 3/21/2016
Industry: Water / Wastewater (WATR) | Products: Belzona 1121 (Super XL-Metal) Belzona 5811 (Immersion Grade) Belzona 5233 Problem : The occasional leaking seal of process water was causing the advanced corrosion attack of the metal substrate of the pump base, which was leading up t... |
||
POSITIVE FEEDBACK ON BELZONA APPLICATION OF A SECONDARY CLARIFIER
Date Created: 3/21/2017
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4131 (Magma-Screed) Belzona 4911 (Magma TX Conditioner), Problem : The secondary clarifiers at the Water Pollution Control Center were pitted and deteriorated due to chemical attack from the biological treatment proce... |
||
BELZONA RECOVERS CONCRETE CLEAR WELL AT A 50-YEAR-OLD WATER PLANT
Date Created: 3/21/2017
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4141 (Magma-Build) Belzona 4154 (Bulkfill Resin) Belzona 4911 (Magma TX Conditioner) Belzona 1121 (Super XL-Metal) Problem : This concrete clear well had 185 linear feet of hairline cracks and corners that were gradually crumbling off as well as exposed rebar. |
||
BELZONA PROTECTS MIXING TANK
Date Created: 3/16/2006
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 5811 (Immersion Grade) Belzona® 4111 (Magma Quartz) Problem : Customer needed protection on their KMnO4 (Potassium Permanganate) mixing tank. |
||
BELZONA REPAIRS BROKEN RBC BASE
Date Created: 3/16/2006
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 4111 (Magma Quartz) Problem : While replacing the gearbox the customer broke the concrete base and anchors. |
||
BELZONA REPAIRS RBC SHAFT
Date Created: 3/16/2006
Industry: Water / Wastewater (WATR) | Application: MPT-Mechanical Power Transmission (MPT) | Products: Belzona® 1111 (Supermetal) Problem : The bearing failed, damaging the shaft. |
||
BELZONA CLEARS CLARIFIER PROBLEM
Date Created: 3/31/2008
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 3921 (GSC Conditioner)Belzona® 5811 (immersion Grade), Problem : 50% of the shield had been eroded away due to corrosion at the water line. A new skirt from the manufacturer would cost over $15,000 and take unduly l... |
||
BELZONA LEAK SEALING EMERGENCY
Date Created: 3/31/2008
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1291 (ES Metal)Belzona 1221 (Super E Metal) Problem : Line sprung a leak in an odd spot right next to a chemical injection nozzle which made the repair impossible with a normal clamp. |
||
BELZONA REBUILDS LIFT PUMP
Date Created: 3/31/2008
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R Metal) Belzona® 1321 (Ceramic S Metal) Problem : Pump had lost efficiency and had to be pulled. The model was foreign and had a four week lead time for parts. |
||
BELZONA PUMP REBUILD
Date Created: 4/1/2008
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R-Metal) Belzona® 1341N (Supermetalglide) Problem : Many of the pumps have never been rebuilt and severe pitting was present. In some cases, it went almost through the casing. |
||
BELZONA INSITU RESTORATION OF SHAFT IN WASTEWATER PLANT
Date Created: 8/24/2012
Industry: Water / Wastewater (WATR) | Application: MPT-Mechanical Power Transmission (MPT) | Products: Belzona® 1111 (Supermetal) Problem : Shaft had become worn and needed insitu repair. |
||
Abrasion protection for sludge screw conveyor
Date Created: 6/23/2022
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 1812 (Ceramic Carbide FP) Problem : The bare steel had a short life expectancy in service. The sludge being transported by this screw was not only highly abrasive but also corrosive - th... |
||
WASTEWATER CLARIFIER REPAIRS COMPLETED QUICKLY WITH BELZONA
Date Created: 5/27/2016
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4131 (Magma-Screed) Problem : Running track on top of wall for distributor arm had been experiencing damage. The distributor wheels had caused impact & abrasion damage over time. C... |
||
BELZONA 1814 SCREW CONVEYOR PROTECTION
Date Created: 11/8/2024
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 1814 Problem : Screw conveyor used to skim sludge from the base of a silo at a biomass plant. |
||
Roll Crusher abrasive lining
Date Created: 10/22/2024
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 1812 (Ceramic Carbide FP) Problem : Roll crushers in use in a sludge processing plant were experiencing excessive wear in service. |
||
Belzona repairs waste water clarifier base
Date Created: 5/20/2024
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4131 (Magma-Screed), Belzona 4911 (Magma TX Conditioner) Problem : A waste water concrete clarifier had a worn uneven surface after years of harsh service. This meant the clarifier could not operate properly & waste s... |
||
Belzona 3131 long term roof protection
Date Created: 11/27/2024
Industry: Water / Wastewater (WATR) | Application: RPA-Roof Problem Areas (RPA) | Products: Belzona 3131 (WG Membrane) Problem : Two large roofs were experiencing leaks due to ageing mineral felt. This was causing issues to the operations inside the buildings. |
||
Belzona repairs & protects Phosphoric Acid Bund
Date Created: 1/3/2023
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4131 (Magma-Screed), Belzona 4341 (Magma CR4), Belzona 4911 (Magma TX Conditioner) Problem : The previous coating within the bund had been corroded away leaving the underlying concrete susceptible to damage. A long term repair & protective sol... |
||
Belzona Repairs and Protects a Concrete Clarifier
Date Created: 5/21/2019
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4911 (TX Conditioner), Belzona 4131 (Magma-Screed), Problem : Replacing the concrete with more concrete would not solve the base issue. Shutdown time was also an issue on the repair. An abrasion-resistant system ... |
||
Belzona seals leaks in clear water storage tank
Date Created: 1/3/2023
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1981 (SuperWrap II), Belzona 5811DW2 (DW Immersion Grade) Problem : Due to the design of the tank sealing these joints from the external is very challenging. A solution that ensured the leaks would be stopped was requi... |
||
BELZONA REPEAT APPLICATION ON PUMP DIFFUSER
Date Created: 4/7/2008
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R Metal) Belzona® 1341 (Supermetalglide) Belzona® 5811 (Immersion Grade) Belzona® 1121 (XL Metal) Problem : Corrosion protection and efficiency enhancement of equipment |
||
Belzona 1341 Solution on Brass Impeller
Date Created: 8/16/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1341 (Supermetalglide) Problem : Customer was looking for a protective coating for the impeller. Belzona was required to provide a suitable solution. |
||
Belzona Repeatedly Offers Rebuilding and Efficiency Coating Solutions for OEM Pump Manufacturers
Date Created: 3/5/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal), Belzona 1341 (Supermetalglide), Belzona 1391T Problem : Pumps at OEM manufacturers require rebuilding and coating to repair corrosion and damage and to improve efficiency. |
||
BELZONA SURFACED TRACK OF SETTLEMENT BASIN PASSES THE TEST
Date Created: 2/7/2012
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona® 4111 (Magma-Quartz) Belzona® 5811 (Immersion Grade) Problem : Scraper wheels and weather had caused wear to the concrete. |
||
Belzona Saves Wastewater Plant Significant Replacement Cost
Date Created: 8/1/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R-Metal) Belzona® 1321 (Ceramic S-Metal) Problem : Worn edges caused propeller to be in-efficient. Client was going to replace with new equipment. |
||
Severe Corrosion stopped with Belzona 3111 (Flexible Membrane)
Date Created: 4/19/2005
Industry: Water / Wastewater (WATR) | Application: RPA-Roof Problem Areas (RPA) | Products: Belzona 3111 (Flexible Membrane) Belzona 3921 (GSC Surface Conditioner) Belzona 9311 (Reinforcing Membrane Sheet) Problem : Severe corrosion caused paint delamination on top of exposed reclaim tank walls. |
||
BELZONA INCREASES EFFICIENCY OF MULTI-STAGE PUMP
Date Created: 9/20/2014
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1341 (Supermetalglide) Problem : The city wanted to coat the pump to increase efficiency. |
||
Belzona Applies a Protective System on a Grit Snail
Date Created: 1/9/2018
Industry: Water / Wastewater (WATR) | Products: Belzona 1811 (Ceramic Carbide) Problem : Grit running through the grit removal system wears through the protective coating and the stainless steel housing. |
||
Belzona SuperWrap II Salvages Sewage Treatment Plant
Date Created: 1/15/2018
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona SuperWrap II System Problem : Carbon steel pipe elbows have been suffering over time from external corrosion due to weathering. The Customer required the restoration of metal loss ... |
||
BELZONA ENHANCES EFFICIENCY OF NEW PUMPS
Date Created: 7/2/2010
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Belzona® 1341 (Supermetalglide) Problem : Need of corrosion/erosion protection and increased pumping efficiency |
||
EMERGENCY LEAK SEALING ON TRANSFORMER WITH BELZONA
Date Created: 7/6/2009
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 1291 (ES Metal) Belzona® 1161 (Super UW Metal) Problem : Leaks of transformer oil on porous and cracked welds |
||
Belzona Repairs Pump Mouth
Date Created: 6/7/2022
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R Metal) Belzona 1321 (Ceramic S Metal) Belzona 5821 Problem : Heavy corrosion in the area where the propeller runs. |
||
Pipe Repair at a Pump Station
Date Created: 6/7/2022
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1111 (Super Metal) Belzona 5811 (Immersion Grade) Problem : Heavy corrosion of the internal of the pipes needed repairing to ensure protection of dyke. |
||
Corrosion Protection 2 x Industrial Storage Tanks with Belzona 5811
Date Created: 8/1/2019
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5811 (Immersion Grade) Problem : Corrosion on the internal linings of two large storage tanks at a large industrial plant in Poland. |
||
Chemical Protection of a Sediment Tank
Date Created: 7/15/2019
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4111 (Magma Quartz) Belzona 5821 Belzona 9211 (Supergrip Aggregate) Problem : The accumulation of sediment on the bottom and walls of the tank. The penetration of aggressive dirt into the depths of concrete, chemical corrosion o... |
||
Reinforcement Of Sewage Pipeline With Belzona SuperWrap II In A Sewage Treatment Plant
Date Created: 1/6/2021
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 9611 (ES-Metal) Belzona 1221 (Super E-Metal) Belzona 1161 (Super UW-Metal) Belzona 1111 (Super-Metal) Belzona 1983 (Superwrap II) Belzona 9381 (SuperWrap II Reinforcement Sheet) Belzona 9382 (Release Film) Belzona 5811 (Immersion Grade) Problem : The pipe eroded over time and this resulted in a weakening of the pipe wall and weld seams. The pipe wall was very thin and there was a risk of an eco... |
||
Belzona 2311 repairs Waste Incineration Plant Conveyor Belt
Date Created: 8/10/2020
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 2311 and Belzona 2911 Problem : There were a number of tears in the conveyor belts due to the medium that was being transported along the conveyors. If the belts had torn completely ... |
||
Belzona coats a Hydro Power pump shaft
Date Created: 4/1/2020
Industry: Water / Wastewater (WATR) | Application: MPT-Mechanical Power Transmission (MPT) | Products: Belzona 1311 (Ceramic R-Metal), Belzona 1321 (Ceramic S-Metal), Belzona 5811 (Immersion Grade), Belzona 9411 (Release Agent) Problem : Conditions during operation: Head: 760 m, Power: 195 MW, Speed: 600 rpm Flow rate: 30 m³ / s. A slight increase in abrasion is to be expected within t... |
||
Belzona SuperWrap II used at a Sewage Treatment Plant
Date Created: 10/22/2020
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1981 (Superwrap II Resin) Belzona 9381 Belzona 9382 Belzona 1111 (Super Metal) Belzona 9611 (ES Metal) Belzona 5821 Belzona 2911 (Elastomer QD Conditioner) Belzona 2211 ( MP High Build Elastomer) Belzona 9341 Problem : Erosion and perforation at the base off the steel tank. |
||
BELZONA REBUILDS WASTEWATER PUMP IMPELLER
Date Created: 5/28/2008
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Belzona® 1321 (Ceramic S Metal) Problem : The impeller was badly eroded and damaged due to grit and solids running through the pump |
||
BELZONA RESTORES RIVER WATER PUMP
Date Created: 10/13/2009
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Belzona® 1321 (Ceramic S Metal) Problem : Erosion corrosion caused by sand and solids drawn from the river. |
||
Weakened pipe reinforced with plate bonding and SW
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1161 (Super UW-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap Problem : A pipe in a wastewater plant needed had suffered from external corrosion and metal loss over the years. |
||
Protection of Wastewater Centrifuge
Date Created: 4/9/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal), Belzona 1341 (Supermetalglide) Problem : The centrifuge was suffering from erosion-corrosion and scale buildup. They needed a product that would protect the equipment but also help reduce the... |
||
Pipe in a wastewater pumping station reinforced with Belzona SWII
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1121 (Super XL-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap, Belzona 5811 (Immersion Grade) Problem : The pipe section was suffering from general external corrosion. The pipe had become weakened from severe metal loss. This pipe section never got flood... |
||
Structural reinforcement of weakened pipe in a wastewater plant
Date Created: 10/2/2024
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1161 (Super UW-Metal), Belzona SuperWrap II Problem : The existing pipe had become severely weakened over time and they needed to reinforce it to prevent future problems. |
||
BELZONA SUPERWRAP II APPLICATION AVOIDS WATER SUPPLY INTERRUPTION
Date Created: 4/28/2017
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona Superwrap II Belzona 5811 (Immersion Grade) Belzona 4131 (Magma Screed) Problem : Several pipes were suffering from significant external corrosion due to water leaks occurring through the sealing system between the pipes and the con... |
||
BELZONA PROTECTS NEW BUILT WATER FILTERS
Date Created: 11/24/2016
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1391T Problem : New water debris filters required protection against erosion-corrosion at temperatures up to 130C |
||
BELZONA MADE A QUICK AND EASY BELT REPAIR
Date Created: 9/14/2013
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 9111 (Cleaner Degreaser) Belzona 2911 (Elastomer QD Conditioner) Belzona 2311 (SR Elastomer) Problem : A tear in a conveyor belt carrying solid waste threatened to shut down this section of the plant. The belt has previously been repaired by hot vulcan... |
||
Belzona protect new water distribution pipework
Date Created: 8/14/2019
Industry: Water / Wastewater (WATR) | Products: Belzona 5821 Problem : Protection against corrosion / erosion on new sections of pipework |
||
TANK ROOF REPAIR
Date Created: 10/17/2005
Industry: Water / Wastewater (WATR) | Application: RPA-Roof Problem Areas (RPA) | Products: Belzona® 3111 (Flexible Membrane) Belzona® 9311 (Reinforcing Sheet) Belzona® 3911 (PSC Surface Conditioner) Problem : The roof was badly deteriorated. Concrete cracked due to the very hot and dry environment, as well as strong UV attack and potable water was being con... |
||
BELZONA PROTECTS WASTEWATER PUMP FOR 25 YEARS
Date Created: 12/1/2014
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R Metal) Belzona 1321 (Ceramic S Metal) Problem : This wastewater pump was originally rebuilt in 1989 with Belzona when the lower portion of the pump bowl had eroded severely causing small pinholes to... |
||
BELZONA REPAIRS WASTE WATER SLUDGE TANKS
Date Created: 5/16/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 1161(Super UW-Metal) Belzona® 5831(ST-Barrier) Problem : All three tanks were suffering from through wall corrosion at the vapour interface level. The tanks could not be taken off line due to demand and any ... |
||
BELZONA PLATE BONDING SOLUTION FOR SLUDGE TANK
Date Created: 11/25/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 1161(Super UW-Metal) Belzona® 5831(ST-Barrier) Problem : Tank was suffering from a through wall corrosion at the lowest panel level. The tank could not be taken off line due to demand and any repairs would h... |
||
BELZONA COLD PLATE BONDING SOLUTION FOR SLUDGE TANK
Date Created: 11/25/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1161 (Super UW-Metal) Belzona 5831 (ST-Barrier) Problem : The primary sludge tank was suffering from through wall corrosion at the lowest panel level. The tank could not be taken off line due to demand and an... |
||
BELZONA SOLVES THROUGH WALL CORROSION ON SLUDGE BUFFER TANK
Date Created: 9/19/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1161 (Super UW-Metal) Belzona 5831 (ST-Barrier) Problem : The sludge buffer tank was suffering from through wall corrosion at the vapour interface level. The tank could not be taken off line for an extended t... |
||
BELZONA SUPERWRAP II RESTORES PIPE AT DAM WALL
Date Created: 4/7/2015
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona SuperWrap II Belzona 1981 Resins Belzona 9382 Release Film Problem : The pipe had suffered from corrosion over time which had caused the formation of pits on the surface of the steel. This resulted in weakening of the p... |
||
BELZONA REPAIRS AND PROTECTS CONCRETE AROUND HANDRAIL POSTS
Date Created: 8/20/2015
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4131 (Magma-Screed) Belzona 4911 (Magma TX Conditioner) Problem : The concrete around the handrail posts was badly spalled. Some of the damage was from a combination of environmental (freeze thaw effect) and proximit... |
||
BELZONA PROTECTS DOOR TO DIGESTER AGAINST CORROSION
Date Created: 8/25/2015
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 5811 (Immersion Grade) Problem : The previous door was suffering from corrosion. The customer wanted long-term protection on the new door prior to installation. |
||
EFFICIENCY ENHANCEMENT KEEPS SLUDGE MOVING
Date Created: 3/12/2014
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1341 (Supermetalglide) Problem : The Dewatering Centrifuges were suffering from struvite and required regular cleaning and maintenance to keep them in operational condition |
||
INTERNAL COATING FOR CENTRIFUGAL PUMP
Date Created: 3/17/2014
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1321 (Ceramic S-Metal) Belzona 9111 (Cleaner Degreaser) Problem : A customer wanted to protect and expand the life of a new pump due to installed at the plant to replace the existing pump which was suffering from cor... |
||
SHAFT REPAIR AT WASTE WATER PLANT
Date Created: 3/11/2014
Industry: Water / Wastewater (WATR) | Application: MPT-Mechanical Power Transmission (MPT) | Products: Belzona 1111 (Super Metal) Belzona 9411 (Release Agent) Problem : Shaft became worn due to bearing failure |
||
Expansion joints replaced at Wastewaster plant
Date Created: 8/20/2014
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 2211 (MP Hi-Build Elastomer) Belzona 2911 (Elastomer QD Conditioner) Belzona 4141 (Magma-Build) Belzona 4911 (Magma TX Conditioner) Problem : Existing joint material had become defective allowing leaking of fluid. |
||
BELZONA REPAIRS CLARIFIER WITH 2" GOUGE
Date Created: 8/20/2015
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4131 (Magma-Screed) Belzona 4911 (Magma TX Conditioner) Problem : The sweeper arm in the clarifier had sagged over the year’s and had worn a 2 inch gouge around the diameter of the tank. |
||
BELZONA PROTECTS HELLAN FLUID STRAINER FROM WASTE
Date Created: 8/21/2015
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1212 Belzona 1331 Problem : Erosion/Corrosion from the waste water. |
||
BELZONA REPAIRS HOLE ON SCUM TANK
Date Created: 8/21/2015
Industry: Water / Wastewater (WATR) | Application: HEX-Heat Exchangers (HEX) | Products: Belzona 1161 (Super UW-Metal) Belzona 9111 (Cleaner Degreaser) Problem : Hole caused by corrosion. |
||
Coated Secondary Containment Areas
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4311 (Magma CR1), Belzona 4911 (Magma TX Conditioner), Belzona 5811 (Immersion Grade), Belzona 9111 (Cleaner Degreaser) Problem : The new water treatment facility had four rooms with secondary containment areas for storing chemicals that was required to have protecting coating to... |
||
Leaking Porous Weld Repair
Date Created: 4/12/2024
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1111 (Super Metal), Belzona 9111 (Cleaner Degreaser) Problem : Weld Joint on stainless steel pipe was leaking due to a porosity and slag inclusion |
||
CLARIFIER HEADWORKS GET QUICK FIX WITH BELZONA
Date Created: 7/31/2015
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4111 (Magma-Quartz) Belzona 5831 (ST-Barrier) Problem : The headworks of a clarifier were covered with a plate to reduce H2S odor. This caused chemical attack to the concrete. |
||
Turbine impeller protected using Belzona.
Date Created: 10/8/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R-Metal), Belzona 2141 (ACR-Fluid Elastomer), Belzona 2941 (Elastomer SP-Conditioner) Problem : The turbine was damaged by the erosion-corrosion process. |
||
Anti-corrosive protection of the gutter on the water treatment plant.
Date Created: 10/3/2024
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5811 (Immersion Grade) Problem : Corrosive damage to the gutter occurs during water purification at the wastewater treatment plant. |
||
BELZONA PROVIDES PROTECTION FROM HOT GASES AT WATER TREATMENT PLANT
Date Created: 8/23/2011
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 1392 Belzona® 4311 (Magma CR1) Problem : Sulphides, Sulphates, Chlorides, Ammonia, etc. in the gas caused pitting corrosion in the unit after 10 months. |
||
Belzona Protects River Back-Flow Valves
Date Created: 10/17/2017
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1111 (Super Metal) Belzona 5811 (Immersion Grade) Belzona 2211 (MP Fluid Elastomer) Problem : The valves suffered from erosion and corrosion through continued use. The valve was so badly damaged that it leaked even when shut. |
||
Drain grate for swimming pool frame gets Belzona 4111 repair
Date Created: 10/2/2024
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4111 (Magma-Quartz) Problem : The grate perimeter seal was cracked, allowing water to migrate through and get under the tiles. |
||
BELZONA PROTECTS CONTACTER TANK
Date Created: 12/4/2009
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 5111 (Ceramic Cladding) Belzona® 5911 (Ceramic Conditioner) Belzona® 4111 (Magma Quartz) Problem : Sodium Hypochlorite vapors had destroyed the concrete walls above the water line. The previous coating, an inexpensive commodity product, failed in th... |
||
BELZONA RESEATS WEAR RINGS WITHOUT MACHINING
Date Created: 9/29/2009
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1121 (Super XL Metal) Problem : Erosion of wear ring seats caused vibration to the pump which needed repairs on site. |
||
BELZONA PROTECTS PIPEWORK ON SEWAGE OVERFLOW SYSTEM
Date Created: 9/25/2013
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 5811 (Immersion Grade) Problem : The newly fitted pipework had a paint system which was already showing signs of failure. Client required system to provide long term corrosion protect... |
||
BELZONA REBUILDS CLARIFIER RUNNING TRACK
Date Created: 8/19/2005
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona® 4111 (Magma-Quartz) Belzona® 4911 (Magma TX Conditioner) Problem : The wheels had caused between 2mm and 10mm wear to the concrete and were not running smoothly. |
||
BELZONA PROTECTS RUBBER PIPES AT WWTP FROM UV ATTACK
Date Created: 12/22/2005
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona® 3211 (Lagseal) Belzona® 3921 (GSC Conditioner) Problem : UV attacks the rubber over a period of time causing it to degrade and eventually become brittle. |
||
BELZONA PROTECTS AERATOR IN WATER TREATMENT PLANT
Date Created: 4/4/2008
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona® 1321 (Ceramic S Metal) Problem : The welded component required protection from bi-metallic corrosion |
||
BELZONA RELINES WATER PUMP
Date Created: 5/14/2012
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R-Metal) Belzona® 1321 (Ceramic S-Metal) Problem : The pump was suffering erosion/corrosion after 3 years in service due to total breakdown of existing unknown coating. |
||
Pump Oil Sump Not All Its "Cracked" Up To Be
Date Created: 11/30/2007
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona® 2111 (D&A Hi-Build Elastomer) Problem : Large oil sump for the shaft bearing at the top of the pump was experiencing cracking from harmonic vibration. As the company that produced the pump ... |
||
RESTORATION OF BRONZE IMPELLER WITH BELZONA
Date Created: 2/16/2006
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic-R Metal) Belzona® 1321 (Ceramic-S Metal) Problem : This pump impeller, 1 of 4, normally running 24/7 had eroded to the point of replacement. |
||
BELZONA REFORMS CLARIFIER SHAFT
Date Created: 6/22/2012
Industry: Water / Wastewater (WATR) | Application: MPT-Mechanical Power Transmission (MPT) | Products: Belzona® 1321 (Ceramic S-Metal) Problem : The damaged shaft had to be repaired but it could not be dismantled so an in-situ repair was required. |
||
BELZONA REPAIR OF RUBBER IMPELLER
Date Created: 2/22/2006
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona® 2131 (D&A Fluid Elastomer) Belzona® 2311 (SR Elastomer) Problem : Whilst casing had little damage, the impeller vanes were very badly damaged and needed rebuilding. |
||
BEARING HOUSING REPAIR WITH BELZONA
Date Created: 7/28/2005
Industry: Water / Wastewater (WATR) | Application: MPT-Mechanical Power Transmission (MPT) | Products: Belzona® 1111 (Super Metal) Problem : Housing damage after bearing seized leading to increased clearance. |
||
BELZONA REBUILDS OVERSIZE KEYWAY
Date Created: 7/21/2005
Industry: Water / Wastewater (WATR) | Application: MPT-Mechanical Power Transmission (MPT) | Products: Belzona® 1111 (Super Metal) Problem : Broken edge of the keyway seat. Insufficient contact area for the load transmission. |
||
BELZONA REPAIRS CORRODED PIPEWORK ON METHANE TANK
Date Created: 7/26/2005
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona® 4301 (Magma CR1 Hi-Build) Belzona® 3121 (MR7) Problem : Corroded area and leaking hole on the Methane pipework. |
||
BELZONA ENHANCES PUMP EFFICIENCY
Date Created: 7/28/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Belzona® 1341 (Supermetalglide) Problem : General erosion/corrosion damage leading to reduced pump efficiency |
||
BELZONA PROTECTS SLUDGE PUMP
Date Created: 7/28/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R-Metal) Belzona® 1321 (Ceramic S-Metal) Problem : Pump casing severely eroded and corroded during operation. |
||
GALVANIC CORROSION IN WATER MAKER REPAIRED WITH BELZONA
Date Created: 11/30/2007
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona® 1111 (Super Metal) Belzona® 1321 (Ceramic S Metal) Problem : Galvanic corrosion caused by the failure of the insulating gasket caused severe corrosion and under cut the existing glass flake coating. Base materia... |
||
Protection of elbows in municipality potable water plant
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1111 (Super Metal), Belzona 1341N (Supermetalglide) Problem : Pipe elbows had a concrete liner which was very deteriorated and at times concrete chunks became loose in the system which was unacceptable. |
||
Repair of wear and through wall defect on Volute of Pumps and Protection of Pumps from further corrosion
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1111 (Super Metal), Belzona 1321 (Ceramic S-Metal) Problem : Through wall defect and wear in pump caused by sewage and particles in wastewater was to be repaired and lined with intention of getting more lives ou... |
||
Refurbishment and protection of Water-Polymer Mixture Tank from further corrosion
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5811 (Immersion Grade) Problem : Tank was very badly corroded and required refurbishment and protection |
||
Protection of stainless-steel scrubber vessel from chemical attack
Date Created: 4/8/2024
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1111 (Super Metal), Belzona 4311 (Magma CR1) Problem : Newly fabricated stainless-steel scrubber vessels were put in service without a coating thinking the stainless-steel will provide enough protection. A... |
||
BELZONA REPAIRS 4 YEAR OLD PRIMARY SETTLEMENT TANK
Date Created: 10/10/2017
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 2211 (MP Hi-Build Elastomer) Belzona 4111 (Magma Quartz) Problem : Shortly after the PST tank was constructed 4 years ago, the expansion joints between the 82 x top blocks failed and so were repaired several times by ... |
||
Belzona Restores Concrete Settlement Tank Walls
Date Created: 11/20/2020
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4131 (Magma-Screed) Belzona 2211 (MP High-Build Elastomer) Problem : The top of the concrete walls of multiple FST's had suffered from abrasive wear due to the action of the wheels that drive the rotating separator arms... |
||
Oxygenation Tank Rebuilt and Protected for Years to Come
Date Created: 12/20/2017
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 4124 (Bulkfill) Belzona 5811 (Immersion Grade) Belzona 1812 (Ceramic Carbide FP) Belzona 9811 (Alumina Tiles) Problem : The tank had not had protection for years, and as a result the concrtete walls and floors were in a bad shape. Some sections showed eriosion as deep a... |
||
Belzona Repairs Corroded Pump Casing
Date Created: 10/18/2017
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R-Metal) Belzona 1321 (Ceramic S-Metal) Problem : The pump had suffered extensive corrosion. |
||
BELZONA PROTECTS DIGESTER
Date Created: 8/19/2008
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 5811 (Immersion Grade) Problem : Severe corrosion occuring in vapour space at top of tank on walls and underside of the roof. Also internal pipework being attacked. |
||
BELZONA PROTECTS DRUM THICKENERS AGAINST CORROSION
Date Created: 12/22/2007
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 1111 Super-Metal Belzona® 5811 Immersion Grade Problem : The mechanical drum thickener casings at this plant had corroded in service from contact with Chlorides & Sulphates present in the wastewater sludge b... |
||
Belzona Rebuilds & Protects Pump Impeller
Date Created: 5/13/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super-Metal) Belzona® 1321 (Ceramic S-Metal) Problem : Impeller had moved on its shaft causing it to run against the casing. This resulted in severe abrasive wear and mechanical damage. |
||
CREATING CUTLASS BEARINGS WITH BELZONA
Date Created: 7/20/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 2131 (D&A Fluid Elastomer) Problem : Original bearings were being worn out rapidly by the high sand content in the water. |
||
BELZONA PROTECTS CITIES WATER PUMPS
Date Created: 2/3/2008
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R Metal) Belzona® 1341 (Supermetalglide) Problem : Failure due to high cavitation caused by bad suction conditions that could not be changed. |
||
WASTE WATER PLANT DIGESTER SEALED WITH BELZONA
Date Created: 12/19/2005
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 4521 (Magma-Flex Fluid) Belzona® 4911 (Magma TX Conditioner) Problem : Loss of oxygen rich gas caused customer to re-enrich with oxygen monthly. Design conditions called for re-enrichment only three times per year. |
||
BELZONA REFURBISHES LABORATORY WORKTOPS
Date Created: 12/14/2007
Industry: Water / Wastewater (WATR) | Application: WPA-Wall Problem Areas (WPA) | Products: Belzona® 5811 (Immersion Grade) Problem : Severely degraded counter tops needed to be resurfaced with a chemically resistant coating. |
||
BELZONA PROTECTS THICKENER FROM CORROSION
Date Created: 3/15/2012
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 5811 (Immersion Grade) Problem : In just six months of use the equipment was already showing signs of corrosion from corrosion and chemical atack from the waste water sludge |
||
Corrosion in water storage tanks
Date Created: 10/2/2024
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1121 (Super XL-Metal) Problem : Excessive corrosion on the interior steel of the water storage tank. A new lining could not be installed until the corrosion damage was repaired. |
||
BELZONA RESTORES WORN ARCHIMEDES SCREW
Date Created: 4/29/2013
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 1811 (Ceramic Carbide) Problem : Erosion and corrosion caused the edges of the 58 inch long archimedes screw flights to be worn down, thus losing efficiency at Wastewater Treatment Pl... |
||
Belzona 1341 provides a non-stick coating to pump
Date Created: 5/1/2020
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1341 Problem : Clogging in pumps due to the high content of Struvite (aka MAP - magnesium-ammonia-phosphate) in wastewater. MAP is an alkali with PH9 so it is a corr... |
||
STORM TANK AT SEWAGE WORKS REPAIRED WITH BELZONA PLATE BONDING
Date Created: 9/24/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1211 (E Metal) Belzona 1161 (UW Metal) Problem : The tank was suffering from corrosion issues around the seam areas. In two places the corrosion was through wall and raw sewage was leaking out of the... |
||
STORM TANK AT SEWAGE WORKS REPAIRED WITH BELZONA PLATE BONDING
Date Created: 9/24/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1211 (E Metal) Belzona 1161 (UW Metal) Problem : The tank was suffering from corrosion issues around the seam areas. In two places the corrosion was through wall and raw sewage was leaking out of the... |
||
AERATION CHANNEL LEAKS REPAIRED WITH BELZONA
Date Created: 9/24/2013
Industry: Water / Wastewater (WATR) | Application: WPA-Wall Problem Areas (WPA) | Products: Belzona® 2211 (MP Hi Build Elastomer) Problem : The construction and movement joints were leaking raw sewage to ground. Previous repairs were failing and only channeling the sewage in to the drains... |
||
AERATION CHANNEL LEAKS REPAIRED WITH BELZONA
Date Created: 9/24/2013
Industry: Water / Wastewater (WATR) | Application: WPA-Wall Problem Areas (WPA) | Products: Belzona® 2211 (MP Hi Build Elastomer) Problem : The construction and movement joints were leaking raw sewage to ground. Previous repairs were failing and only channeling the sewage in to the drains... |
||
Belzona Repairs and Protects Screw conveyor
Date Created: 3/10/2017
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 1511 (Super HT-Metal) Belzona 9811 Belzona 1813 Problem : The new screw conveyor suffered surprisingly fast wear by erosion and bi-metallic corrosion. The shaft of the screw conveyor had been topped with a st... |
||
Belzona Saves A Ruptured Effluent Tank
Date Created: 4/30/2019
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 1111 (Super Metal) Belzona 9611 (ES-Metal) Problem : Corroded and through-wall defects on effluent tank created leaks in the system. |
||
Belzona Protects New Sea Water Pumps
Date Created: 1/17/2020
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1341 (Supermetalglide) Problem : New pumps requiring internal protection prior to going into service |
||
Belzona Superwrap II Restores Strength to 26 Metre Sewage Pipeline
Date Created: 8/12/2022
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona SuperWrap II Belzona 1121 (Super XL-Metal) Belzona 4131 (Magma-Screed) Problem : The heavily corroded, 900mm diameter pipe is the main sewage line for a nearby town and if the issue was not rectified, there would be a huge cost for... |
||
Belzona Restores Safety to Fire Escape Stairway
Date Created: 12/15/2011
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona® 4411 (Granogrip) Problem : The concrete steps had worn and the current safety grip system had become almost none existent due to heavy foot traffic and weathering. A member of s... |
||
Belzona Repairs 82 Expansion Joints on a Primary Settlement Tank
Date Created: 9/18/2017
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: • Belzona 4111 (Magma-Quartz) • Belzona 2211 (MP Hi-Build Elastomer) Problem : Existing expansion joints had failed. The customer then tried to use a cementitious material to repair them but this also cracked and failed. |
||
Dewatering Centrifuge Scroll Rebuilding and Protection with Belzona
Date Created: 1/31/2019
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 1311 (Ceramic R-Metal) Belzona 1812 (Ceramic Carbide) Problem : The Dewatering Centrifuge Scroll was damaged and metal chunks were broken due to aggressive wear and abrasion of waste material. All this lead to the ... |
||
CLARIFIER TROUGHS RESTORED WITH BELZONA
Date Created: 9/13/2013
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 5811 (Immersion Grade) Problem : Concrete clarifier troughs had deteriorated to point of exposing the aggregate in the concrete. |
||
COMPLETE ZONE SAFETY WITH BELZONA
Date Created: 9/23/2013
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona® 4131 (Magma Screed) Belzona® 5811 (Immersion Grade) Belzona® 4311 (Magma CR1) Belzona® 2111 (D&A Hi Build Elastomer) Belzona® 5231 (SG Laminate) Problem : Both road areas needed a chemical lining that would be resistant to repeated splashes and spills. In addition, the areas had to have good traction for... |
||
BELZONA SEALS REMOTE PUMP HOUSE FLOORS
Date Created: 5/24/2016
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 5231 (SG Laminate) Belzona 2121 (D & A Hi-Coat Elastomer) Belzona 9341 (Reinforcement Tape) Problem : The client had a series of remote pump houses with diesel storage tanks inside and these facilities were seldom visited. Should there be a leak of die... |
||
BELZONA SECURES AERATION BASIN JOINTS
Date Created: 9/19/2014
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 2211 (MP Hi-Build Elastomer) Belzona 2911 (Elastomer QD Conditioner) Problem : The client was aware of Belzona's quality and sought use of appropriate Belzona materials to seal leaking expansion joints. Existing material was of ... |
||
BELZONA PROTECTS CONTAINMENT AREA AT A TREATMENT PLANT
Date Created: 9/25/2014
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4111 (Magma Quartz) Belozna 5811 (Immersion grade) Problem : Spalled floor areas needed repair and coating to prevent further damage and provide secure containment for potential spillage Treatment chemicals stor... |
||
BELZONA REPAIRS PST AT WATER TREATMENT PLANT
Date Created: 9/19/2013
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona® 4131 (Magma Screed) Belzona® 2211 (MP Hi-Build Elastomer) Problem : Walls of the running track had become badly worn and damaged over time due to rotation of the distributor. Some areas had been unsuccessfully repaired... |
||
BELZONA STOPS LEAK DRAIN PIPE AND HOT WELL PUMP
Date Created: 7/27/2010
Industry: Water / Wastewater (WATR) | Application: HEX-Heat Exchangers (HEX) | Products: Belzona 1161 (Super UW Metal) Belzona 1291 (ES-Metal) Belzona 9341 (Reinforcing Tape) Problem : Leaking drain pipe and hot well pump at Water Treatment Plant |
||
Belzona Coats Submersible Pump for Potable Water
Date Created: 8/23/2016
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 5812DW Belzona 1111 (Super Metal), Problem : After several years in use this pump needed to be repaired and protected due to erosion/corrosion. Being a filtration plant a product with NSF 61 appr... |
||
BELZONA PROVIDES ABRASION RESISTANT PROTECTION FOR SCREW CONVEYOR
Date Created: 10/7/2016
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona 1812 (Ceramic Carbide FP) Problem : As part of its operation in a treatment plant's slurry clarifier, the screw conveyor was transporting dehyrdated slurries. The hard particles in the s... |
||
HOLED HYDRO TURBINE RUNNER REPAIRED WITH BELZONA
Date Created: 6/13/2007
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1121 (Super XL Metal) Belzona® 1341 (Supermetalglide) Problem : Entrained solids and cavitation caused severe damage to the edges of the runner. Holes and pitting are evident on the runner vanes. |
||
Belzona Repairs Concrete Well Base
Date Created: 3/28/2024
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona 4111 (Magma-Quartz), Belzona 4911 (Magma TX Conditioner), Belzona 5821 Problem : The concrete base was suffering from chemical attack caused by the waste in the process fluid. The bottom of the well was so severely damaged that the... |
||
Belzona Coats Aging Carbon Steel Pipeline
Date Created: 1/4/2024
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 5821 Problem : The customer was looking for a coating system for lining carbon steel pipe work predominantly for the new construction of pipe bridges, pump stations,... |
||
Belzona protects new seawater filters for desalination
Date Created: 4/13/2021
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5821 Problem : Due to the corrosive nature of seawater and erosion caused by suspended solids, a protective coating is necessary to mitigate potential damage to the ... |
||
HIGH CHROME PUMP RESTORED WITH BELZONA
Date Created: 4/26/2019
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona 2911 (Elastomer QD Conditioner) Belzona 2111 (D&A High Build Elastomer) Problem : Despite the high hardness of the pump casing material, the high volume of solids in the process fluid has caused entrainment erosion. |
||
Wastewater repair and protection with Belzona
Date Created: 2/15/2021
Industry: Water / Wastewater (WATR) | Application: VPF-Valves, Pipes and Fittings (VPF) | Products: Belzona 1111 (Super Metal) Belzona 4111 (Magma-Quartz) Belzona 5811 (Immersion Grade) Problem : Internal corrosion of the pipelines has lead to severe degradation of the substrate including heavy pitting. In some areas, the loss of wall thickness... |
||
BELZONA INCREASES THE SERVICE LIFE OF SLUDGE MIXERS FROM NEW
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 2121 (D&A Hi-Coat Elastomer) Problem : High level of erosion causes severe damage to the housing. The vessel manufacturer offered the customer an upgrade of the standard mixer which feature... |
||
BELZONA PERFORMANCE IMPROVEMENT PROGRAM (PIP) CUTS RUNNING COSTS DRAMATICALLY
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1111 (Super Metal) Belzona® 1341 (Supermetalglide) Problem : Reduced flow and pressure coupled with motor overheating |
||
BELZONA PUMP COATING LOOKS EXCELLENT AFTER 7-1/2 YEARS
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1311 (Ceramic R Metal) Belzona® 1321 (Ceramic S Metal) Problem : The spool was leaking and had to be replaced. Upon inspection of the pump it was discovered that the previous Belzona® 1321 coating, done 7-1/2 year... |
||
BELZONA PERFORMANCE IMPROVEMENT PROGRAM (PIP) BOOSTS OUTPUT
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1111 (Supermetal) Belzona® 1341 (Supermetalglide) Problem : Reduced output from booster pumps which required standby unit to operate continuously to provide adequate flow |
||
BELZONA SEALANT FOR METHANE POWERED ENGINE PAD
Industry: Water / Wastewater (WATR)
| Application:
FPA-Floor Problem Areas (FPA)
| Products:
Belzona® 2221 (MP Fluid Elastomer) Problem : Old cork expansion joint material hardened, allowing vibration to crack the floor outside of the joint area. |
||
BELZONA FABRICATION OF ROTARY LOBES
Industry: Water / Wastewater (WATR)
| Application:
PDP-Positive Displacement Pumps (PDP)
| Products:
Belzona® 2131 (D&A Fluid Elastomer) Belzona® 2911 (Q.D. Conditioner) Belzona® 4411 (Granogrip) Belzona® 9411 (Release agent) Problem : Rotary pump lobes damaged by entrained solids. |
||
BELZONA LEAK SEALING ON VALVES
Industry: Water / Wastewater (WATR)
| Application:
VPF-Valves, Pipes and Fittings (VPF)
| Products:
Belzona® 1311 Belzona® 1321 (Ceramic S-Metal) Problem : Erosion-corrosion leading to water leakage. |
||
BELZONA REPAIRS WASTEWATER PUMP
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1311 (Ceramic R-Metal) Problem : Pumps were suffering from severe erosion around the volute. It was difficult to remove the unit for repair due to its size and location. |
||
BELZONA PUMP DIFFUSER PROTECTED
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1311 (Ceramic R Metal) Belzona® 1321 (Ceramic S Metal) Problem : Erosion/corrosion and cavitation |
||
BELZONA DAM LOCK SEALED
Industry: Water / Wastewater (WATR)
| Application:
GSS-Gaskets, Seals and Shims (GSS)
| Products:
Belzona® 2211 (MP Hi-Build Elastomer) Belzona® 2911 (QD Conditioner) Problem : Lower seal on locks were leaking due to irregular metal-on-metal seal caused by cavitation. |
||
BELZONA RENOVATES DILAPIDATED WATER TOWER
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4911 (Magma TX Conditioner) Belzona® 4141 (Magma-Build) Problem : The concrete support structure and water tank was deteriorated. Pieces of concrete were falling off exposing passersby to injury. |
||
BELZONA REPAIRS 30 YEAR OLD VALVES
Industry: Water / Wastewater (WATR)
| Application:
VPF-Valves, Pipes and Fittings (VPF)
| Products:
Belzona® 1311 (Ceramic R-Metal) Belzona® 1341 (Supermetalglide) Belzona® 5811 (Immersion Grade) Problem : After 30 years of use, valves demonstrated severe damage from erosion-corrosion. |
||
BELZONA STOPS METHANE LEAK
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4111 (Magma-Quartz) Belzona® 5811 (Immersion Grade) Problem : The 30-year-old tank had cracks and pin holes allowing methane gas to escape. |
||
BELZONA SPECIFIED FOR OEM EQUIPMENT AT WASTEWATER TREATMENT FACILITY
Industry: Water / Wastewater (WATR)
| Application:
VPF-Valves, Pipes and Fittings (VPF)
| Products:
Belzona® 1321 (Ceramic S-Metal) Problem : Specified as protection against erosion-corrosion. |
||
BELZONA SAVES SLUDGE PUMP
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1321 (Ceramic S-Metal) Problem : Impeller was frozen by rust. It would not turn. |
||
BELZONA REBUILDS SLUDGE PUMP COMPONENTS
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1311 (Ceramic R-Metal) Belzona® 1321 (Ceramic S-Metal) Problem : Severe erosion had caused unacceptable pump performance. |
||
BELZONA BRIDGES THE GAP
Industry: Water / Wastewater (WATR)
| Application:
VPF-Valves, Pipes and Fittings (VPF)
| Products:
Belzona® 1111 (Super Metal) Problem : Having to connect new, industrial polypropylene pipe to the old iron pipe which is severely pitted, making it impossible to obtain a water tight seal ... |
||
SMOOTH RUNNING WITH BELZONA
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4111 (Magma-Quartz) Belzona® 2131 (D&A Fluid Elastomer) Problem : The running track was badly worn by constant abrasion from the distributor wheels. |
||
BELZONA REPAIRS A CLASSIFIER AND SAVES THE CUSTOMER THOUSANDS IN REPLACEMENT COSTS
Industry: Water / Wastewater (WATR)
| Application:
SHM-Solids Handling Machinery (SHM)
| Products:
Belzona® 1111 (Super Metal) Belzona® 2111 (D&A Hi-Build Elastomer) Problem : The rubber donut type ring was designed too small allowing the adjacent steel to wear through. |
||
LIFT STATION WET WELL STAYS IN SERVICE WITH HELP FROM BELZONA
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4141 (Magma Build) Belzona® 4911 (TX Conditioner) Belzona® 5811 (Immersion Grade) Problem : Hydrogen sulfide attack deteriorated the concrete in the wet well area of a lift station. |
||
BELZONA RESTORES ARCHIMEDES SCREW
Industry: Water / Wastewater (WATR)
| Application:
SHM-Solids Handling Machinery (SHM)
| Products:
Belzona® 1321 (Ceramic S-Metal) Problem : Corrosion/erosion caused the screw blades to wear down. The diameter of the angle was reduced so much that it could not lift the water. |
||
BELZONA REPAIRS DEWATERING CENTRIFUGE
Industry: Water / Wastewater (WATR)
| Application:
SHM-Solids Handling Machinery (SHM)
| Products:
Belzona® 1111 (Super Metal) Belzona® 1811 (Ceramic Carbide) Problem : Sludge constantly got behind wear tiles which caused corrosion as well as erosion of the flights. The unit became unbalanced and tiles frequently dela... |
||
BELZONA KEEPS WATER SAFE TO DRINK
Industry: Water / Wastewater (WATR)
| Application:
FPA-Floor Problem Areas (FPA)
| Products:
Belzona® 4111 (Magma Quartz) Belzona® 3121 (MR7) Belzona® 4151 (Magma Quartz Resins) Problem : Cracks in the roof of the storage tank were allowing the ingress of surface water and contaminating the potable water contained in the reservoir. This... |
||
BELZONA PROVIDES LONG TERM PROTECTION FOR THIS TROUGH
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4131 (Magma Screed) Belzona® 5811 (Immersion Grade) Problem : Previous elastomeric coating started to fail and algae built up and made it very difficult to clean. In addition, the concrete behind the lining began... |
||
BELZONA REPAIRS AND ENHANCES CONCRETE CLARIFIER TROUGHS
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4111 (Magma Quartz) Belzona® 5811 (Immersion Grade) Problem : An old coal tar epoxy system had failed and resulted in damage to the underlying concrete. It also made it very difficult to keep the trough clean and... |
||
BELZONA FOR EMERGENCY LEAK SEALING
Industry: Water / Wastewater (WATR)
| Application:
WPA-Wall Problem Areas (WPA)
| Products:
Belzona® 4211 (Magma Stop) Belzona® 4221 (Magma Seal) Problem : Leaking in the joint between a new, and existing tank. Loss of water estimated at one million gallons per month. |
||
BELZONA STOPS LEAKING IN CONCRETE JOINTS
Industry: Water / Wastewater (WATR)
| Application:
WPA-Wall Problem Areas (WPA)
| Products:
Belzona® 4211 (Magma Stop) Belzona® 4221 (Magma Seal) Problem : Water seepage was occuring at many of the joints in the cast concrete structure. |
||
BELZONA RESTORES POTABLE WATER SUPPLY TO CHINESE CITY
Industry: Water / Wastewater (WATR)
| Application:
VPF-Valves, Pipes and Fittings (VPF)
| Products:
Belzona® 4211 (Magma Stop) Belzona® 4111 (Magma Quartz) Problem : Routine construction above caused physical damage to this 1.2 meter diameter concrete pipeline carrying potable water to Guang Dong Province. |
||
BELZONA PERMANENTLY SECURES HANDRAIL POSTS
Industry: Water / Wastewater (WATR)
| Application:
FPA-Floor Problem Areas (FPA)
| Products:
Belzona® 4151 (Magma Quartz Resins) Problem : Liquid was pooling around these handrails, spalling the concrete and loosening the rails at this municipal sewage plant to such an extent that worker ... |
||
BELZONA REPAIRS SPALLED CONCRETE ON THIS AERATION TANK
Industry: Water / Wastewater (WATR)
| Application:
FPA-Floor Problem Areas (FPA)
| Products:
Belzona® 4111 (Magma Quartz) Problem : Deteriorated concrete around the base of the handrail posts raised safety concerns. |
||
BELZONA ELIMINATES POTENTIAL SAFETY HAZARD
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4131 (Magma Screed) Problem : The damaged concrete at a handrail post was creating a potential safety hazard. |
||
BELZONA STOPS ACTIVE JET FUEL LEAK
Industry: Water / Wastewater (WATR)
| Application:
VPF-Valves, Pipes and Fittings (VPF)
| Products:
Belzona® 1211 (E-Metal) Belzona® 1111 (Super Metal) Problem : The wastewater treatment facility utilizes jet engines for standby power generation. Jet fuel is stored on the premises. Distribution system for JP4 j... |
||
PIPING DISTRIBUTION HEADER REPAIRED WITH BELZONA
Industry: Water / Wastewater (WATR)
| Application:
VPF-Valves, Pipes and Fittings (VPF)
| Products:
Belzona ® 1111 (Super Metal) Belzona ® 5811 (Immersion Grade) Problem : Corrosion as well as erosion deteriorated the entire internal surface of this sludge water piping structure. This pipework transports sludge water fro... |
||
BELZONA SEALS CARBON STEEL DIGESTER DOME
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona ® 2221 (MP fluid Elastomer) Belzona ® 2911 (QD Conditioner) Problem : This 80 foot diameter carbon steel digester dome was originally sealed with a tar pitch.The seal had broken down over the years and was leaking at sev... |
||
BELZONA SEALS CRACKS IN UNDERWATER CONCRETE TANK
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona ® 4111 (Magma Quartz) Problem : Various concrete cracks in the base of this aquaduct leaked copious amounts of water. |
||
BELZONA STOPS CORROSION ON THIS 5,000,000 GALLON TANK
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona ® 3111 (Flexible Membrane) Belzona ® 3921 (GSC Conditioner) Problem : Concrete holding pad settles. Rain water penetrates space between metal tank and concrete pad. Stagnant water causes corrosion. |
||
BELZONA CREATES RUBBER LOBES ON THIS ROTARY PUMP
Industry: Water / Wastewater (WATR)
| Application:
PDP-Positive Displacement Pumps (PDP)
| Products:
Belzona ® 2131 (D&A Fluid Elastomer) Belzona ® 2911 (QD Conditioner) Problem : The two intermeshing rubber lobes in the pump rapidly wear and the clearances increase reducing the pumps efficiency. Replacement of the lobes is nece... |
||
CLASSIC BELZONA PUMP REFURBISHMENT-OUTPUT INCREASES 9.5% AFTER 3½ YEARS
Industry: Water / Wastewater (WATR)
| Application:
CEP-Centrifugal Pumps (CEP)
| Products:
Belzona® 1111 (Super Metal) Belzona® 1341 (Supermetalglide) Problem : Output from the pumps was drastically reduced from the new condition due to corrosion and cavitation damage. |
||
BELZONA LINING FOR ACID CONTAINMENT AREAS
Industry: Water / Wastewater (WATR)
| Application:
TCC-Tanks and Chemical Containment Areas (TCC)
| Products:
Belzona® 4311 (Magma CR-1) Problem : Lining required in bunds to resist acid spills and comply with construction regulations. |
||
BELZONA IN WATERWORKS’ PUMP SAVES OVER $7,200 ANNUALLY
Date Created: 2/8/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1221 (Super E-Metal) Belzona® 1341 (Supermetalglide) Problem : Erosion and bearing problems. |
||
BELZONA REFURBISHES SETTLEMENT TANK AT WATER TREATMENT PLANT
Date Created: 6/6/2012
Industry: Water / Wastewater (WATR) | Application: FPA-Floor Problem Areas (FPA) | Products: Belzona® 4131 (Magma-Screed) Belzona® 2211 (MP Hi-Build Elastomer) Problem : Due to freeze thaw damage and the constant weight of the separator arm, many areas of the running track had become damaged. |
||
BUTTERFLY VALVE REFURBISHED WITH BELZONA
Date Created: 12/10/2006
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1321 (Ceramic – S Metal ) Belzona® 2221 (MP-Fluid Elastomer) Problem : Body badly corroded sand holed in places. In addition rubber seal on valve disc completely deteriorated. |
||
MEDIA FILTERS PROTECTED WITH BELZONA
Date Created: 12/10/2006
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 5811 (Immersion Grade ) Problem : Filters were suffering internal corrosion and required protection to prevent further loss of wall thickness. |
||
Belzona Pump Repair - From A to Z
Date Created: 6/7/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1311 (Ceramic R-Metal) Belzona® 1321 (Ceramic S-Metal) Problem : The pump casing, cut water, straighteners, wear ring and gland housing were all suffering from erosion-corrosion. Also, there was a long crack on the... |
||
DEIONIZER COATED WITH BELZONA
Date Created: 8/29/2005
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 5811 (Immersion Grade) Problem : Failure of rubber lining due to aging and chemical attack. |
||
DAMAGED RUBBER LINING RESTORED
Date Created: 8/29/2005
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona® 2221 (MP-Fluid Elastomer) Problem : Peeled-off lining at welding edges causing under lining corrosion due to sea water penetration between the rubber sheets. |
||
INDUSTRIAL WASTEWATER IMPELLERS REPAIR
Date Created: 8/18/2005
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 2111 (D&A Hi-Build Elastomer) Belzona® 2121 (D&A Hi-Coat Elastomer) Problem : The edges of impellers were broken due to impact, abrasion and corrosion. |
||
Protection of New Vertical Pump for Potable Water Service
Date Created: 7/2/2018
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Belzona® 1341 (Supermetalglide) Problem : Long-lasting NSF approved system was required to protect the potable water pump from erosion-corrosion issue. |
||
Belzona Protects Sewage Separator of A New Project
Date Created: 4/22/2020
Industry: Water / Wastewater (WATR) | Application: TCC-Tanks and Chemical Containment Areas (TCC) | Products: Belzona 5892 Belzona 1511 (Super HT Metal) Problem : The client chose to use Belzona coating system to replace composite panels. |
||
BELZONA RETURNS PIPELINE PIG BACK TO SERVICE
Date Created: 7/19/2009
Industry: Water / Wastewater (WATR) | Application: SHM-Solids Handling Machinery (SHM) | Products: Belzona® 2111 (D&A Hi Build Elastomer) Problem : Wear on the rubber tail causes imbalance in the pig. |
||
FLOW CONTROL VALVE REFURBISHED WITH BELZONA
Date Created: 7/2/2009
Industry: Water / Wastewater (WATR) | Application: CEP-Centrifugal Pumps (CEP) | Products: Belzona® 1111 (Super Metal) Belzona® 1311 (Ceramic R-Metal) Belzona® 1321 (Ceramic S-Metal) Belzona® 5811 (Immersion Grade) Problem : Corrosion and erosion on internal surfaces caused by sewage water. |
Please contact Belzona if you wish to find out more about our products and/or our services.
Contact us