Search Our Know-How in Action Case Studies

166 KHIAs found
Belzona Repairs and Reinforces Crack and Weakened Sewage Pipe in Polymer Plant
Date Created: 9/19/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1982 (SuperWrap II), Belzona SuperWrap II
Problem : Stainless Steel pipe carrying sewage water with polymer particles was cracked and leaking. Customer was convinced after extensive scrutiny and technic...
Belzona Seals Leaking SF6 Flange
Date Created: 8/20/2024
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1981 (SuperWrap II), Belzona SuperWrap, Belzona 7311, Belzona 9111 (Cleaner Degreaser), Monti® MBX® Bristle Blaster®
Problem : The customer was suffering from the loss of SF6 gas from a horizontal pipe joint within a substation building. A solution was required to stop the los...
Leak Repair at Blowdown Elbow at power plant
Date Created: 3/25/2025
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1983 (SuperWrap II), Belzona SuperWrap II, Belzona 9111 (Cleaner Degreaser), Belzona 9411 (Release Agent)
Problem : A high-pressure steam leak was identified at the blowdown elbow of an industrial piping system. The leak posed a significant risk to operational effic...
Pipe Strengthening with Belzona SuperWrap II
Date Created: 4/9/2024
Industry: Local Authorities & Municipalities (LAMU)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1121 (Super XL-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap II
Problem : A 60” carbon steel pipe that had suffered from external corrosion and metal loss over the years. The defective area was about 15 feet. They required a...
Pipe in a wastewater pumping station reinforced with Belzona SWII
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1121 (Super XL-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap, Belzona 5811 (Immersion Grade)
Problem : The pipe section was suffering from general external corrosion. The pipe had become weakened from severe metal loss. This pipe section never got flood...
Weakened pipe reinforced with plate bonding and SW
Date Created: 4/11/2024
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap
Problem : A pipe in a wastewater plant needed had suffered from external corrosion and metal loss over the years.
Belzona SF6-FIX System Stops SF6 Leak
Date Created: 4/12/2024
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1981 (SuperWrap II), Belzona SuperWrap, Belzona 7311
Problem : The Customer has many assets which contain SF6 as an insulating gas. The gas is used in pipework where power distribution lines are enclosed within. A...
Flanges leak sealed in a petrochemical plant.
Date Created: 6/12/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1982 (SuperWrap II), Belzona SuperWrap II, Belzona 9111 (Cleaner Degreaser)
Problem : Product was leaking from flanges and needed sealing for environmental compliance.
Belzona Super wrap on a concrete stand for a pipe at a power station
Date Created: 4/29/2024
Industry: Power (POWR)  |  Application: WPA-Wall Problem Areas (WPA)  |  Products: Belzona 1982 (SuperWrap II), Belzona SuperWrap
Problem : The concrete pedestal holding up a pipe formed a crack over the years of exposure to the elements.
Repair of PVC pipe with leak from failed fiber glass installation
Date Created: 7/30/2024
Industry: Steel & Metal Processing (STEL)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1982 (SuperWrap II), Belzona SuperWrap, Belzona 9111 (Cleaner Degreaser)
Problem : Major leaks was experienced from a failed fiber glass installed earlier by customer to fix problem.
Belzona Super Wrap II Extends Service Life of Water Injection Holding Tank
Date Created: 8/2/2024
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap II, Belzona 9111 (Cleaner Degreaser)
Problem : This water injection holding tank was suffering from internal corrosion causing thin wall throughout the entire vessel. The customer was looking for a...
BELZONA SUPERWRAP II DESIGN SOLUTION
Date Created: 2/23/2024
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1983 (SuperWrap II), Belzona SuperWrap II, Belzona 9111 (Cleaner Degreaser)
Problem : The refinery was experiencing corrosion on their pipe at a port terminal, which required either a large maintenance shutdown, or an alternative soluti...
Tank Repair Composite Wrap
Date Created: 7/23/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap II, Belzona 5111 (Ceramic Cladding)
Problem : Customer had 4 nozzles coming off a tank that experienced corrosion under insulation. The metal on the nozzles were severely pitted and thin. The nozz...
Belzona SuperWrap II Applied on a 58" Flare Line at a Petrochemical Plant in Saudi Arabia
Date Created: 11/10/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1983 (SuperWrap II), Belzona SuperWrap II
Problem : The 58" flare line had experienced significant wall-thickness loss, posing a serious risk to its structural integrity.
Reparación de pitting y pérdida de espesor en tubería de 32 pulgadas con Belzona SuperWrap II
Date Created: 11/10/2025
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1311 (Ceramic R-Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap II
Problem : Tubería subterránea de 32 pulgadas con pitting y defectos de desgaste a lo largo de 3.5 m lineales, originados por posible ampollamiento en recubrimi...
Belzona SuperWrap Repairs Crude Oil Pipeline
Date Created: 1/29/2018
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Pre-fabricated plates were bonded over the scabs and then blasting could be allowed. Belzona SuperWrap II was applied over the defect areas so stop further corrosion and to keep the pipeline in service for 10 years.


Problem : Corrosion Under Insulation had created corrosion scabs to form at the underside of the pipe. Blasting of these scabs was not allowed.
Belzona SuperWrap II prepares for the worst
Date Created: 5/8/2024
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1111 (Super Metal), Belzona 1982 (SuperWrap II), Belzona SuperWrap II, Belzona 5811 (Immersion Grade), Belzona 7311
Problem : This pipework was expected to go through wall within its remaining lifetime. A method had to be employed that would mitigate the risk of this, while a...
Badly deteriorated process tank due to erosion corrosion and high alkalinity refurbished by Belzona.
Date Created: 6/12/2024
Industry: Mining & Quarrying (MINQ)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1121 (Super XL-Metal), Belzona 1341 (Supermetalglide), Belzona 1982 (SuperWrap II), Belzona SuperWrap II, Belzona 5811 (Immersion Grade)
Problem : Process tank was in a deplorable state after years of wear due to erosion corrosion.
Cooling Tower Pipe Leak Repair
Date Created: 1/3/2025
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1982 (SuperWrap II), Belzona SuperWrap, Accessories, Belzona 9111 (Cleaner Degreaser), Belzona 9611 (ES-Metal)
Problem : 1 inch steel pipe had corrosion and was leaking at the pipe seam and socket weld joint
Multiple sea water leaks with structural reinforce with Belzona SuperWrap II
Date Created: 10/20/2025
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1212, Belzona 1982 (SuperWrap II), Belzona SuperWrap II, Belzona 5811DW2 (DW Immersion Grade)
Problem : Having to replace the pipe would take a lot of time and money, also they would have to cut the line.
Pipe spool repaired with Belzona SuperWrap II
Date Created: 10/24/2025
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona SuperWrap II
Problem : A large crack had formed in a pipe spool. This pipe was located deep within a reservoir sump & was impossible to remove without major structural works...
Plastic tank pipe repairs
Date Created: 11/6/2025
Industry: Power (POWR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1221 (Super E-Metal), Belzona 1981 (SuperWrap II)
Problem : A plastic tank had developed several cracks around pipes. A replacement was planned but to get production through to that point a temporary fix was re...
VALVE BODY SUPER WRAP WITH BELZONA 1984
Date Created: 12/9/2025
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1984, Belzona SuperWrap II
Problem : THE VALVE BODY RUNS AT OVER 1000 PSI AND UNDER YEARS OF STRESS CREATED A HAI LINE CRACK IN THE TOP OF THE VALVE BODY. THE ITEM IS OBSOLETE AND CAN NOT...
Belzona 1984 Surface Tolerant Super Wrap II
Date Created: 12/15/2025
Industry: Steel & Metal Processing (STEL)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1984, Belzona SuperWrap II, Monti® MBX® Bristle Blaster®
Problem : The client was dealing with a serious issue of thin walled piping.
Belzona 1984 Super Wrap II
Date Created: 12/16/2025
Industry: Steel & Metal Processing (STEL)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1984, Belzona SuperWrap II, Monti® MBX® Bristle Blaster®
Problem : The customer wanted to do preventive maintenance on some of their older piping to prevent holes from wearing through.
Belzona saves settlement tank on large Holiday Complex
Date Created: 8/1/2025
Industry: Commercial Facilities (COMM)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1111 (Super Metal), Belzona SuperWrap II, Belzona 5831 (ST-Barrier), Belzona 9111 (Cleaner Degreaser)
Problem : Leaks had appeared in the large settlement tank on the effluent plant at a large holiday complex
A damaged spool on a crate Belzona repairs sections of cooling water spools
Date Created: 8/7/2025
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1981 (SuperWrap II), Belzona 7311
Problem : undergoing a planned shutdown, the client encountered issues while breaking into the cooling water system due to seized bolts.
Belzona SF6-FIX on a Voltage Transformer in the Potash Industry
Date Created: 8/12/2025
Industry: Mining & Quarrying (MINQ)  |  Application: GSS-Gaskets, Seals and Shims (GSS)  |  Products: Belzona 1981 (SuperWrap II), Belzona 7311
Problem : The voltage transformer was leaking, including from the machine bolt locations. After recovering the SF6 gas, the system was pressurized to prevent mo...
Methanol Column Skirt Repair
Date Created: 9/8/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1984, Belzona SuperWrap II, Belzona 5811 (Immersion Grade)
Problem : Upon removal of fireproofing from the base of a methanol column, corrosion and pitting damage were observed across the skirt surface. The bottom 30–3...
Slurry Line Leak Repair – Cold-Applied Composite Solution at Cement Plant
Date Created: 9/19/2025
Industry: Mining & Quarrying (MINQ)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1984, Belzona SuperWrap II
Problem : A rubber-lined slurry pipe inside a cement plant has developed an approx 1-inch diameter hole that has penetrated through the wall, resulting in an ac...
Belzona SuperWrap II saves 24" Exhaust Pipe at Steel Mill
Date Created: 10/10/2025
Industry: Steel & Metal Processing (STEL)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona SuperWrap II, Belzona 9111 (Cleaner Degreaser)
Problem : Pipe was previously repaired with fiberglass. Thin gage steel was used to make a form and bonded form with 1212 to pipe. Then we proceeded to wrap pip...
Belzona SuperWrap II Repair & Reinforcement of Seawater Pipelines on LNG Ship
Date Created: 4/26/2025
Industry: Marine (MRNE)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products: Belzona 1212, Belzona 1981 (SuperWrap II)
Problem : The CuNiFe seawater pipelines ranging between DN65 to DN300 on an LNG ship were weakened and leaking due to corrosion. Customer choose to repair the l...
Evaporator Heat Transfer Tube
Date Created: 5/14/2025
Industry: General Industry (GIND)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1984, Belzona SuperWrap II
Problem : The heat transfer tube an 2 of the companies evaporators had become thin-walled and, in places, through-walled. The lead time for a replacement was ...
A series of wide external pipes with a pitted one at the front Externally corroded pipe restored and strengthened
Date Created: 5/20/2025
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1111 (Super Metal), Belzona 1981 (SuperWrap II)
Problem : Customer identified an area of corrosion on their JP-51 pipeline, resulting in reduced wall thickness. The affected section was believed to have thinn...
Plate bonding repair on glass infused tanks ensures integrity of tank
Date Created: 5/22/2025
Industry: Water / Wastewater (WATR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1111 (Super Metal), Belzona SuperWrap II
Problem : Sludge tanks for treatment works required several repairs for external corrosion on glass steel infused tank
Superwrap II repairs on large diameter cooling water pipe
Date Created: 6/12/2025
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1981 (SuperWrap II)
Problem : A cooling water pipe had several through wall defects. These had come from years of erosion & corrosion. The site depended on this pipe for production...
Stern tube showing pitting and metal loss before SuperWrap repair Tube Repair with Belzona SuperWrap
Date Created: 6/16/2025
Industry: Marine (MRNE)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products: Belzona 1982 (SuperWrap II)
Problem : The inboard section of the stern tube presented severe corrosion, with extensive pitting and metal loss that compromised the component’s integrity. Tr...
Belzona 1984 on Sweating Nozzle
Date Created: 6/19/2025
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1984, Belzona SuperWrap II, Belzona 5831 (ST-Barrier)
Problem : CUI led to excessive corrosion. The vessel operates at sub ambient temperatures which leads to sweating substrate.
SF6 Leak Contained with Belzona SF6-FIX Composite Repair
Date Created: 6/25/2025
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1982 (SuperWrap II), Belzona 7311
Problem : The customer had an SF6 leak around a flange that had been a recurring issue. They had tried sealing it with caulking in the past, which helped a bit,...
Belzona SuperWrap II ABS approved system Repairs Leaks USNS PFC Dewayne T. Williams Vessel
Date Created: 2/3/2025
Industry: Marine (MRNE)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1982 (SuperWrap II)
Problem : The vessel was offshore to the Guam Naval Base. Many of the carbon steel pipes in their waste water system had corrosion problems. One of the main pip...
Belzona SuperWrap II ABS approved system Repairs Leak USNS Tippecanoe
Date Created: 2/3/2025
Industry: Marine (MRNE)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1982 (SuperWrap II)
Problem : The vessel was at the Guam Naval Base. There are copper-nickel pipes that run cooling water into the main motors . One of the main pipes had already ...
Belzona Superwrap II Restores Fuel Storage Tank Pipeline
Date Created: 2/26/2025
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1211 (E-Metal), Belzona 1982 (SuperWrap II)
Problem : Pipeline to storage tank was suffering from thin wall corrosion at the weld seam.
Belzona repairs and strengthens severe through wall sliding abrasion to ash pipework at an Energy Recovery Plant
Date Created: 3/26/2025
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1983 (SuperWrap II), Belzona 9111 (Cleaner Degreaser)
Problem : The customer treats 378,000 tonnes of non-recyclable waste each year and diverts at least 95% of the County's residual municipal waste away from landf...
Structural reinforcement of weakened pipe in a wastewater plant
Date Created: 10/2/2024
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona SuperWrap II
Problem : The existing pipe had become severely weakened over time and they needed to reinforce it to prevent future problems.
Rebuild surface and structural strength of diffuser pump component
Date Created: 10/2/2024
Industry: Power (POWR)  |  Application: CEP-Centrifugal Pumps (CEP)  |  Products: Belzona 1121 (Super XL-Metal), Belzona SuperWrap, Belzona 4111 (Magma-Quartz), Belzona 4141 (Magma-Build)
Problem : The customer experienced significant erosion issues within the diffuser pump component and, after conducting tests, determined that the structural str...
Repair of damaged glass fibre flanges
Date Created: 10/3/2024
Industry: Cement (CMNT)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1111 (Super Metal), Belzona 1981 (SuperWrap II)
Problem : Used tanks suffered severe damage to the glass fiber flanges.
Repair of welds in stainless steel gutter.
Date Created: 10/8/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1511 (Super HT-Metal), Belzona SuperWrap II
Problem : The welds started to crack in the stainless steel gutter.
Belzona Prevents Plant Shutdown By Curtailing High Pressure Pipe Leak
Date Created: 12/2/2024
Industry: Steel & Metal Processing (STEL)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1982 (SuperWrap II), Belzona 9111 (Cleaner Degreaser)
Problem : A pipe transporting over 2000 Psi of process water had a leak and a metal plate was welded. However, the pressure of the water would always find a way...
Heavily corroded air handling unit needed some Belzona
Date Created: 12/31/2024
Industry: Heating, Ventilation & Air Conditioning (HVAC)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1981 (SuperWrap II)
Problem : Customer had a tank and wanted to protect with a lining that would resist chemical attack, thereby extending its service life.
BELZONA SUPERWRAP II APPLICATION ON 24 inch ELBOWS
Date Created: 8/4/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1111 (Super Metal), Belzona SuperWrap II
Problem : The customer initially faced problems with the 24'' sea water line, which is used for utility services. The issue was caused by the aggressive sea wat...
Process Tank Shell Crack Leakage
Date Created: 8/14/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1983 (SuperWrap II)
Problem : The customer has a horizontal crack on the shell of a process tank which is leaking.
Ammonium Sulphate Feed Tank Restored with Belzona SuperWrap II
Date Created: 6/21/2024
Industry: Mining & Quarrying (MINQ)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona SuperWrap II
Problem : The Customer’s stainless steel feed tank was suffering from corrosion under insulation and chloride induced stress corrosion cracking.
Belzona SuperWrap application on ammonia pipes
Date Created: 6/24/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1121 (Super XL-Metal), Belzona 1982 (SuperWrap II), Belzona 5811 (Immersion Grade)
Problem : Belzona Superwrap II structural reinforcement system, under ASME PCC-2 standard, for 20 meters of buried pipe. This particular pipe was carrying ammon...
24inch Pipe Leak Repair of Using Belzona 1212 and SuperWrap II
Date Created: 7/29/2024
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona SuperWrap II
Problem : The client is experiencing wall thickness loss which has led to a 6-7 cm hole in the 24-inch crude oil pipeline. The excessive erosion and corrosion o...
Patch Repairs to Ultrasonic Bath
Date Created: 7/29/2024
Industry: Other (OTHER)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1391T, Belzona 1511 (Super HT-Metal), Belzona SuperWrap II
Problem : Having removed a weir plate some years ago which revealed damage and causing leakage from the bath. Repairs of the time have then failed with signific...
Belzona SuperWrap II restores pipe integrity
Date Created: 4/16/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1981 (SuperWrap II)
Problem : A section of cooling water pipework was corroded through wall. A repair was required to prevent any leaks occurring and to restore strength to the pip...
SuperWrap II application to GFRP Spools
Date Created: 4/17/2024
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1111 (Super Metal), Belzona 1983 (SuperWrap II)
Problem : Deteriorated / aged GFRP pipe spools that in turn have cracked at the flange to pipe spool area and are leaking
Belzona Trials New SF6 Leak Solution
Date Created: 4/9/2024
Industry: Power (POWR)  |  Application: GSS-Gaskets, Seals and Shims (GSS)  |  Products: Belzona 1981 (SuperWrap II), Belzona 7311
Problem : SF6 is a gas which is used throughout the electricity industry as an insulating medium in switchgear. It provides many tangible benefits, however it i...
REGULAR BELZONA SUPERWRAP II ON LOW SPECIFICATION PIPING SYSTEMS
Date Created: 2/27/2024
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1111 (Super Metal), Belzona 1161 (Super UW-Metal), Belzona 1981 (SuperWrap II)
Problem : Due to years of neglected priority of maintenance, the client was experiencing severe corrosion challenges on their low-specification piping systems. ...
Belzona Superwrap System helps maintain cooling system of Naval Vessel engines
Date Created: 3/1/2024
Industry: Marine (MRNE)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1982 (SuperWrap II)
Problem : Bronze pipe system with cooling water was set going into the Naval Ship engine room. Pipes had sharp changes and angles causing internal erosion. The ...
Ebonite tank suffering from degradation Belzona System Protects Ebonite Tanks
Date Created: 3/5/2024
Industry: Other (OTHER)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1111 (Super Metal), Belzona 1392 (Ceramic HT2), Belzona 1981 (SuperWrap II)
Problem : A global aluminium manufacturing company has been experiencing degradation to their Ebonite-coated steel tanks which were subject to chemical attack i...
Belzona SuperWrap 2 repairs chemical scrubber
Date Created: 3/28/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1111 (Super Metal), Belzona 1981 (SuperWrap II)
Problem : Chemical attack had caused through wall defects within a chemical scrubber. H2S reacting with water to form sulphuric acid was the main cause.
Belzona SuperWrap II repairs and strengthens ash chutes
Date Created: 4/3/2024
Industry: Other (OTHER)  |  Application: SHM-Solids Handling Machinery (SHM)  |  Products: Belzona 1983 (SuperWrap II)
Problem : The customer burns non-recyclables and re-use the energy from the combustion. The ash left from burning comes down the chutes wearing holes due to sli...
Damaged and cracked bellows between convolutions BELZONA SUPERWRAP II APPLICATION ON MONEL 400 BELLOWS BETWEEN CONVOLUTIONS
Date Created: 4/4/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1983 (SuperWrap II)
Problem : There was a small crack in the Monel which needed terminating and filling with Belzona 1511. The bellow also required strengthening.
Belzona seals leaks in clear water storage tank
Date Created: 1/3/2023
Industry: Water / Wastewater (WATR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1981 (SuperWrap II), Belzona 5811DW2 (DW Immersion Grade)
Problem : Due to the design of the tank sealing these joints from the external is very challenging. A solution that ensured the leaks would be stopped was requi...
Wellhead Leak Repair
Date Created: 1/18/2023
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products: Belzona 1121 (Super XL-Metal), Belzona 1981 (SuperWrap II), Belzona 9611 (ES-Metal)
Problem : A hole present in the casing did not allow gas lift pressure to accumulate. If the accumulation of pressure is not achieved, then oil cannot be produc...
Belzona Superwrap 2 system repairs storage tank
Date Created: 2/10/2023
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1111 (Super Metal), Belzona 1981 (SuperWrap II)
Problem : A leak had developed in a storage tank due to corrosion.
Fractured GRP pipe repaired with Belzona Super Wrap 2
Date Created: 3/30/2023
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212, Belzona 1983 (SuperWrap II)
Problem : A GRP pipe had shattered causing a partial shutdown of a power plant
Belzona Stopped Pipe Leak
Date Created: 3/31/2023
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1981 (SuperWrap II), Belzona 9111 (Cleaner Degreaser), Belzona 9611 (ES-Metal)
Problem : There were a cooling water pipe with leaking holes
Belzona SuperWrap II secures integrity of pipeline
Date Created: 4/18/2023
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1983 (SuperWrap II)
Problem : At a factory in Rotterdam area, integrity of a pipline was critical due to decreasing of wall-thickness. The pipeline was important for the production...
Belzona SuperWrap II System Saves 120k
Date Created: 5/18/2023
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1982 (SuperWrap II), Belzona 4141 (Magma-Build)
Problem : The customer had a clamp previously put on a hole in the condensate line. The clamp started leaking and they were going to replace them at this time.
Belzona Trials New SF6 Leak Solution to Seal the Deal.
Date Created: 12/1/2023
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1981 (SuperWrap II), Belzona 7311
Problem : Sulfur Hexafluoride (SF6) is 23,500x more aggressive to the atmosphere than CO2, therefore, losses must be accounted for. Environmental Agencies who ...
Reinforcement of an Ammonia Tank using Belzona SW2.
Date Created: 1/24/2024
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1121 (Super XL-Metal), Belzona SuperWrap II, Belzona 5831LT
Problem : The roof of an Ammonia (NH3) tank showed signed of weakening due to prolonged corrosion. In order to restore structural integrity, we'll be reinforcin...
Belzona Super Wrap II Repair to Main Sewage Pipe
Date Created: 10/7/2021
Industry: ()  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super Metal) Belzona SuperWrap II


Problem : Following impact damage, the 800mm diameter, GRP sewerage pipe had cracked. The crack ran around the complete circumference of the pipe.
BELZONA SUPERWRAP II SUCCESSFULLY TACKLES A LIVE LEAK REPAIR
Date Created: 2/26/2018
Industry: Power (POWR)  |  Products:

Belzona 1212 Belzona Superwrap II System


Problem : The pipe burst after an outage causing the plant to shutdown.
Biomass plant pipe repairs
Date Created: 1/17/2020
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1982 (SuperWrap II)
Problem : Welding was not an option in this environment & the plant was keen to keep this tank running as the majority of the plant's operation depended on it.
Belzona SuperWrap seals weeping storage tank
Date Created: 11/10/2010
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona® Superwrap


Problem : Vertical weld was found to be very porous and fuel oil was weeping from a 2 mm through wall defect. No corrosion or thin wall area was detected. Defec...
GAS LINE REPAIRED WITH BELZONA SUPERWRAP SYSTEM
Date Created: 11/10/2010
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona® Superwrap


Problem : Gas line was suffering from wall thickness loss due to internal corrosion. A thin wall defect of dimensions 2.1x2.4x0.25" was detected on a section of...
BELZONA® SUPERWRAP PIPE REPAIR
Date Created: 7/27/2011
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona® SuperWrap


Problem : There were two 10mm holes through wall defects in the pipe caused by local bacterial corrosion. Prior to the application, the defects were sealed with...
BELZONA STORAGE TANK PATCH REPAIR
Date Created: 10/4/2011
Industry: Oil & Gas (OILG)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona® SuperWrap


Problem : A vertical weld was found to be porous and product was weeping from a tiny porous spot less than 2mm in diameter. There was no corrosion or thin walli...
BELZONA SUPERWRAP IN A REFINERY
Date Created: 11/15/2011
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona® SuperWrap


Problem : Corrosion occurs where the buried section of pipeline re-emerges above ground. The high humidity at ground level causes severe corrosion to these expo...
BELZONA SUPERWRAP WATER/CONDENSATE PIPE REPAIR
Date Created: 5/14/2012
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona® SuperWrap


Problem : An area of the pipe system had lost 2/3 of its original wall thickness due to internal corrosion. The affected area was expected to go through-wall wi...
BELZONA REPAIRS HYDROCARBON TRANSFER LINES ONLINE
Date Created: 8/27/2013
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona® SuperWrap


Problem : The pipelines were suffering from external corrosion, which had led to thin walls with minimum thickness in some places reaching 1.4mm, whereas the or...
Belzona SuperWrap Allows Drilling to Continue
Date Created: 11/21/2017
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona SuperWrap II


Problem : Due to long lead time fabricating new sections of pipe, Belzona SuperWrap was used to reinstate the required strength to keep the high pressure lines ...
Belzona SuperWrap Repairs Offshore Pipes
Date Created: 11/23/2017
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II System 


Problem : External Corrosion caused damage to the pipe, they also wanted to seal the thread-o-lets, which were no longer required. The repair had to be complian...
Belzona SuperWrap II Salvages Sewage Treatment Plant
Date Created: 1/15/2018
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II System


Problem : Carbon steel pipe elbows have been suffering over time from external corrosion due to weathering. The Customer required the restoration of metal loss ...
BELZONA SUPERWRAP II STRENGTHENS CORRODED GAS PIPE
Date Created: 11/2/2015
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona Superwrap II

Belzona 1111 (Super Metal)

Belzona 1311 (Ceramic R-Metal)


Problem : The asset owner assigned a shutdown period, totalling 7 days. Welding was not an option; the application required a cold applied solution. Due to th...
BELZONA SUPERWRAP II SUCCESSFULLY TACKLES AN EMERGENCY PIPE LEAK REPAIR
Date Created: 8/29/2017
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1212 Belzona Superwrap II composite repair system: Belzona 9381 - reinforcing fabric Belzona 1982 - impregnation resin Belzona 9382 - release film


Problem : Rupture in the water pipe line causing erosion of the surrounding area and the road above the line.
Belzona Strengthens Nozzles of TEG Flash Tanks on Offshore Platform
Date Created: 8/12/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super- Metal)
Belzona 1983 (Belzona Superwrap II Resin)
Belzona 9381
Belzona 9382
Belzona 9111 (Degreaser)
Belzona 9611


Problem : Due to the damage of the original insulation layer, nozzles of the TEG flash tank were corroded under the insulation layer (CUI). The nozzles had deve...
A series of pipes and valves at a power plant Emergency Seawater Butterfly Valves Application Using Belzona SuperWrap II
Date Created: 3/4/2024
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1982 (SuperWrap II), Belzona 2211 (MP Hi-Build Elastomer), Belzona 2911 (Elastomer QD Conditioner), Belzona 9111 (Cleaner Degreaser)
Problem : Two 72-inch seawater butterfly valves were severely damaged by cavitation, with one suffering from through wall defects. The seawater flow is 50,000 m...
Belzona materials repair, protect and improve severally damaged diffuser for pump station
Date Created: 8/27/2024
Industry: Water / Wastewater (WATR)  |  Application: CEP-Centrifugal Pumps (CEP)  |  Products: Belzona 1111 (Super Metal), Belzona 1982 (SuperWrap II), Belzona 2141 (ACR-Fluid Elastomer), Belzona 2941 (Elastomer SP-Conditioner), Accessories
Problem : Following the decision to rebuild a pump station for mechanical wear issues, it was unexpectedly discovered that there was severe cavitation damage ha...
Sand Filter Repair
Date Created: 9/4/2024
Industry: Steel & Metal Processing (STEL)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1161 (Super UW-Metal), Belzona 1212, Belzona 1982 (SuperWrap II), Belzona 4111 (Magma-Quartz), Belzona 9611 (ES-Metal)
Problem : The filter tank was leaking in several areas. The base of the tank had very thin walls. It was in such bad shape it was unsafe to do the repairs from...
Belzona ® SuperWrap II Provides Corrosion Protection for Buried Piping
Date Created: 4/1/2020
Industry: ()  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1161 (Super UW-Metal)

Belzona SuperWrap II


Problem : Thin wall and pitted surface on this pipeline.
Belzona SuperWrap II used at a Sewage Treatment Plant
Date Created: 10/22/2020
Industry: Water / Wastewater (WATR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona 1981 (Superwrap II Resin)

Belzona 9381

Belzona 9382

Belzona 1111 (Super Metal)

Belzona 9611 (ES Metal)

Belzona 5821  

Belzona 2911 (Elastomer QD Conditioner)

Belzona 2211 ( MP High Build Elastomer)

Belzona 9341


Problem : Erosion and perforation at the base off the steel tank.
Strengthening of a Storage Tank with Belzona SuperWrap II
Date Created: 7/16/2019
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1981 - Belzona Superwrap II

Belzona 9381 - Reinforcement Sheet

Belzona 9382 - Release Film


Problem : Storage Tank shell deterioration and the wall of the tank thinning. Restoration of stiffness and nominal strength of the tank's shell.
BELZONA COMPLIANT SUPERWRAP REPAIR ON RISER WELLHEAD CASING
Date Created: 10/15/2017
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (SuperMetal)

Belzona SuperWrapII System


Problem : Severe corrosion on 17 years old 18" production riser on a North sea oil producing platform had resulted in a critical through wall defect. The riser ...
BELZONA SUPERWRAP II RESTORES PIPE AT DAM WALL
Date Created: 4/7/2015
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II

Belzona 1981 Resins

Belzona 9382 Release Film


Problem : The pipe had suffered from corrosion over time which had caused the formation of pits on the surface of the steel. This resulted in weakening of the p...
Belzona SuperWrap II Patch Repair on Tank
Date Created: 7/14/2020
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1221 (Super E-Metal)

Belzona 1981 (SuperWrap II)

Belzona 9381 (SuperWrap II Reinforcement Sheet)


Problem : External corrosion on the exterior of a tank causing a loss in material substrate.
Belzona® SuperWrap II On-site Application for CUI
Date Created: 4/1/2020
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1981 (SuperWrap II)

Belzona 9381 (Reinforcing Sheet)

Belzona 9382 (Release Film)


Problem : Corrosion under insulation(CUI).
Reinforcement Of Sewage Pipeline With Belzona SuperWrap II In A Sewage Treatment Plant
Date Created: 1/6/2021
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 9611 (ES-Metal)

Belzona 1221 (Super E-Metal)

Belzona 1161 (Super UW-Metal)

Belzona 1111 (Super-Metal)

Belzona 1983 (Superwrap II)

Belzona 9381 (SuperWrap II Reinforcement Sheet)

Belzona 9382 (Release Film)

Belzona 5811 (Immersion Grade)


Problem : The pipe eroded over time and this resulted in a weakening of the pipe wall and weld seams. The pipe wall was very thin and there was a risk of an eco...
Belzona Superwrap II Repair of Refinery Pipe
Date Created: 8/21/2019
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1212

Belzona 1981 Superwrap II 


Problem : Customer reported a through wall defect in a 6" pipe. Production was severely limited because of the leak, so the customer needed a repair carried out...
Belzona Solution for Corroded Riser Casing
Date Created: 4/11/2019
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1982 

Belzona 9381 

Belzona 9611


Problem : Leaked and severe corroded surfaces were observed on splash zone of riser casing.
Belzona Repairs and Protects a Sand Filter in a Swimming Pool
Date Created: 11/28/2018
Industry: Buildings & Structures (BSTR)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1981(SuperWrap II)

Belzona 9381 (Reinforcement cloth)

Belzona 5811 (Immersion grade)


Problem : The inside of this sand filter in a swimming pool was badly damaged by corrosion and chemical attacks, especially chloride. After grit blasting the su...
BELZONA SUPERWRAP II SAVES LEAKING SOUR CRUDE TANK
Date Created: 12/30/2017
Industry: Oil & Gas (OILG)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona 1111 (Super-Metal)

Belzona 1982 (Superwrap II)

 

 


Problem : The sour crude tank started leaking and the production had to be shut down. Originally there were 3 holes discovered leaking in the tank. The Customer...
Belzona Superwrap II Restores Strength to 26 Metre Sewage Pipeline
Date Created: 8/12/2022
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II

Belzona 1121 (Super XL-Metal)

Belzona 4131 (Magma-Screed)


Problem : The heavily corroded, 900mm diameter pipe is the main sewage line for a nearby town and if the issue was not rectified, there would be a huge cost for...
BELZONA SUPERWRAP II EXTENDS LIFE OF A HIGH TEMPERATURE PIPELINE BY 5 YEARS
Date Created: 8/20/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1511 (Super HT Metal)

Belzona 1983 (SuperWrap II Resin)

Belzona 9381 (SuperWrap II Reinforcement Sheet)

Belzona 9382 (Release Film)


Problem : The 406 mm diameter pipe had developed a critical (Class 3) through wall defect calculated at 40 x 40 mm. The operating temperature was 90°C and the o...
BELZONA SUPERWRAP II REPAIRS UNDERGROUND PIPELINE ADDING 15 YEARS SERVICE LIFE
Date Created: 8/20/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (SuperMetal)

Belzona 1982 (SuperWrap II Resin)

Belzona 9381 (SuperWrap II Reinforcement Sheet)

Belzona 9382 (Release Film)


Problem : The underground pipeline (O/D = 355.6 mm) had developed a critical (Class 3) thin wall defect with only 2.7 mm wall thickness remaining. The critical ...
BELZONA SUPERWRAP II PROTECTS UNDERGROUND PIPELINE
Date Created: 4/5/2017
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1161 (Super UW Metal)

Belzona SuperWrap II


Problem : The pipe external wall had corroded due to the long-term humid environment. Pitting corrosion had led to significant wall thinning.
BELZONA SUPERWRAP II APPLICATION AVOIDS WATER SUPPLY INTERRUPTION
Date Created: 4/28/2017
Industry: Water / Wastewater (WATR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona Superwrap II

Belzona 5811 (Immersion Grade)

Belzona 4131 (Magma Screed)


Problem : Several pipes were suffering from significant external corrosion due to water leaks occurring through the sealing system between the pipes and the con...
UNDERGROUND PIPE REPAIRED WITH BELZONA SUPERWRAP II
Date Created: 5/27/2016
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II

Belzona 9381 (Reinforcement Tape)

Belzona 1982 (SuperWrap II)


Problem : Internal local corrosion, detected by inspection pig, had created a thin-wall defect in the pipe, which had a design pressure rating of 100 bar(g).
SUBTERRANEAN BELZONA SUPERWRAP II APPLICATION
Date Created: 5/27/2016
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II

Belzona 9381 (Reinforcement Tape)

Belzona 1982 (SuperWrap II)


Problem : Inspection pigs had detected external local corrosion, which had created a thin-wall defect in the pipe.
BELZONA SUPERWRAP II SOLUTION FOR CRUDE OIL PIPELINE
Date Created: 6/17/2016
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II

Belzona 5811 (Immersion Grade)


Problem : Pipeline had suffered thin-wall defects in eight separate areas.
Belzona Superwrap II saves FPSO
Date Created: 6/24/2019
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1121 (XL-Metal)

Belzona 1982 (SuperWrap II)


Problem : Corroded flange and fasteners on the High Pressure Fuel Gas Heater inlet and outlet. The operating pressure of the heater is 24 bar at 30°C on the in...
Belzona SuperWrap II Sets Sail
Date Created: 1/17/2018
Industry: Marine (MRNE)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona SuperWrap II System

Belzona 1321 (Ceramic S-Metal)


Problem : Loss of steel, leading to thin walling on the boat's hull. This damage has occured due to corrosion within the marine environment. The asset owner was...
BELZONA SUPERWRAP II PATCHES SEAWATER BULK MEDIA FILTER VESSEL
Date Created: 4/10/2015
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 1212

Belzona 1291 (ES-Metal)

Belzona 1982 (SuperWrap II Resin)

Belzona 9381 (SuperWrap II Reinforcement Sheet)

Belzona 9382 (Release Film)


Problem : Damage to the external part of the bottom of the vessel due to corrosive environment and seawater transported in the vessel.
Hot Ore no problem for Belzona
Date Created: 10/2/2019
Industry: Steel & Metal Processing (STEL)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1251 (HA-Metal)

Belzona 1511 (Super HT-Metal)

Belzona 1983 (SuperWrap II) Belzona 9381


Problem : The hot ore is highly abrasive, causing a loss of wall thickness in some areas of the T-section. Further degradation would result in catastrophic fail...
Belzona restores structural integrity and stops leak.
Date Created: 3/10/2021
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1161 (UW Metal)

Belzona Superwrap II 1982

Belzona 9381 (SuperWrap II Reinforcement Sheet)

Belzona 9382 (Release Film)

Belzona 9111 (Cleaner Degreaser)


Problem : Corrosion and thinning of the pipeline had failed on most welds. There was an area on a T-junction where the line was leaking extensively. Due to the ...
Oil Refinery Adopts Belzona Composite Pad for Pipeline Repair
Date Created: 9/9/2022
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II

Belzona 1111 (Super Metal)


Problem : The client was experiencing significant external corrosion on several of their main pipelines. These pipelines transport process fluids around the ref...
Belzona SuperWrap II Novel Nuclear Insert
Date Created: 1/17/2018
Industry: Power (POWR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona SuperWrap II System

Belzona 1161 (Super UW-Metal)

Belzona 1321 (Ceramic S-Metal)


Problem : Damp conditions within the area have caused the breakdown of concrete surroundings and corrosion of the pipework, leading to significant loss of wall ...
BELZONA SUPERWRAP II SEALS THROUGH CRACKS ON A 90 DEGREE FLANGE FOR A CHILLER PUMP
Date Created: 12/31/2017
Industry: Fluid Flow (FLOW)  |  Application: CEP-Centrifugal Pumps (CEP)  |  Products:

Belzona 1111 (Super Metal)

Belzona Superwrap II


Problem : The Customer attempted to repair the cracks. However, leaks still existed after the pump was reinstalled onto the chiller return line and tested. The ...
BELZONA SUPERWRAP II REPAIRS 6" OPEN DRAIN SYSTEM
Date Created: 10/16/2017
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (SuperMetal)

Belzona SuperWrap II System


Problem : Internal corrosion caused multiple through-wall defects on the pipes. 
Offshore repair of a riser pipe
Date Created: 10/10/2014
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1121


Problem : Cavitation near the flange, erosion between flange and T-section. Surface preparation created through-wall defects because of the thin remaining thick...
BELZONA PREVENTS CORROSION DAMAGE TO 18' RISER
Date Created: 8/26/2015
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 1982 (SuperWrap II)

Belzona 9111 (Cleaner Degreaser)

Belzona 9381 (Reinforcement Sheet)

Belzona 9382 (Release Film)


Problem : Corrosion damage to riser.
Heat Exchanger Emergency Repair with Belzona Superwrap II
Date Created: 6/10/2021
Industry: Food & Drink (FOOD)  |  Application: HEX-Heat Exchangers (HEX)  |  Products:

Belzona 1511 (Super HT-metal)

Belzona 1983 (Superwrap II)

Belzona 9831 (SWII Reinforcement Sheet)

Belzona 9382 (Release film)


Problem : The flange failed which needed a high temperature solution to delay replacement until the next shutdown.
Structural Reinforcement of Nozzle with Belzona SW II
Date Created: 11/18/2019
Industry: ()  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1982 (Superwrap II)

Belzona 9381 (Carbon Fiber Reinforcement Mesh)

Belzona 9382 (Release Film)


Problem : Nozzle welded to the bottom of the tank showing accelerated signs of internal corrosion. Fluid: Oxygen Scavenger Pressure: 1 kg/cm2 Temperature: 26°C ...
Belzona Gives New Life to Fan Blades
Date Created: 4/11/2019
Industry: Chemical & Petrochemical (PETR)  |  Application: FBC-Fans, Blowers and Compressors (FBC)  |  Products:

Belzona 5111 (Ceramic Cladding)

Superwrap II


Problem : Deposit, erosion and mechanical damage of FRP fan blades for cooling tower were observed during turnaround period
Belzona SuperWrap II Patch Repairs Leaking Vessel Welds
Date Created: 11/17/2021
Industry: General Industry (GIND)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona 1111 (Super Metal)

Belzona 1981 (SuperWrap II)

Belzona 9381


Problem : Welding was undesirable due to the potential for further cracking in the welds. This could potentially cause even more leaks.
Marine Sewage tank repaired with Belzona
Date Created: 12/3/2021
Industry: Marine (MRNE)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1212

Belzona 1981 (Superwrap II Resin)

Belzona 9381 (Superwrap II Reinforcement)

Belzona 5811 (Immersion Grade)


Problem : Replacing the tank was not possible due to it's location in the bowels of the ship. Previous coating systems had not lasted as long as hoped.
Corroded vessel repaired with Belzona Superwrap II
Date Created: 8/5/2022
Industry: General Industry (GIND)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1511 (Super HT-Metal), Belzona 1983, Belzona 9381,
Problem : Welding had been attempted but had failed, leaks reappeared around the welded seams of the doubler plates that had been installed.
Belzona Seals & Reinforces a Water Pipeline at a Nuclear Plant
Date Created: 8/9/2022
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1212

Belzona 1161 (UW-Super Metal)

Belzona SuperWrap II (Belzona 1982 Resin)

Belzona 9111 (Degreaser)

Belzona 9341 (Reinforcement Sheet)


Problem : The pipeline was greatly corroded (mainly external corrosion) which led to the formation of a live leak at a weld.
BELZONA SUPERWRAP II RETURNS PIPING BACK TO SERVICE IN 48 HOURS
Date Created: 8/20/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1983 (SuperWrap II Resin)

Belzona 9381 (SuperWrap II Reinforcement Sheet)

Belzona 9382 (Release Film)


Problem : The 220mm diameter pipe had developed a critical (Class 3) thin wall defect at the bend. The operating temperature was 95°C and the operating pressure...
Belzona SuperWrap II for Pitted Piping
Date Created: 10/6/2021
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1212 

Belzona 1161 (Super-UW Metal)

Belzona 1982

Belzona 9381


Problem : Localized corrosion in the form of deep pits was on the verge of holing through.
Belzona Repairs Cracked Head
Date Created: 10/6/2021
Industry: Chemical & Petrochemical (PETR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona 1511 (Super HT-Metal)

Belzona 1983

Belzona 9381 (SWII reinfrocement sheet)

Belzona 1593


Problem : New head would cost upwards of $75,000 and would have a 6 month lead time.
BELZONA SUPERWRAP II EXTENDS LIFE OF PIPING BY 10 YEARS
Date Created: 8/20/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1983 (SuperWrap II Resin)

Belzona 9381 (SuperWrap II Reinforcement Sheet)

Belzona 9382 (Release Film)


Problem : The 250 mm diameter pipe had developed a critical (Class 3) through wall defect at the bent. The operating temperature was 50°C and the operating pres...
Permanent Leak Repair on Aging Lead and Oakum Pipe Joint
Date Created: 7/22/2025
Industry: Buildings & Structures (BSTR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1984, Belzona 4141 (Magma-Build), Belzona 4911 (Magma TX Conditioner)
Problem : During the refurbishment of an old piping system within a commercial building, the customer discovered an active leak at a lead and oakum joint. These...
Autoclave Repair using Belzona Superwrap II
Date Created: 11/1/2022
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1111 (Super-Metal), Belzona 1983 (Superwrap II Resin), Belzona 9381, Belzona 9382,
Problem : Leaks on the weld seam of the water-cooled jacket of this process vessel.
Belzona Superwrap II Application inside Marine Sewage Tank
Date Created: 12/1/2020
Industry: Marine (MRNE)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1121 XL Metal

Belzona 1981 (Superwrap II)

Belzona 9381

Belzona 9382

Belzona 5811 Immersion Grade


Problem : No hot work was allowed in the area so welding was out of the question. Cold plate bonding was first considered over the full floor & up the walls of ...
BELZONA SUPERWRAP II ENSURES THE SAFETY OF AN OFFSHORE PLATFORM
Date Created: 7/21/2015
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 1982

Belzona 9111 (Cleaner Degreaser)

Belzona 9382


Problem : The integrity of the riser was compromised due to severe damage caused by external corrosion. The asset owner needed to protect the surface of the ris...
Belzona SuperWrap II Patch Saves Tank
Date Created: 11/22/2017
Industry: General Industry (GIND)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II System

Belzona 5811 (Immersion Grade)


Problem : Several areas of the tank had a loss of metal thickness due to corrosion under insulation.
BELZONA SUPERWRAP II MEETS GAS PIPELINE OPERATOR REQUIREMENTS
Date Created: 10/13/2015
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona 9611 (ES-Metal) - (previously named 1291)

Belzona 1161 (Super UW-Metal)

Belzona 1982 (SuperWrap II)

Belzona 9381 (Reinforcement Sheet)

Belzona 9382 (Release Film)

Belzona 9111 (Cleaner Degreaser)


Problem : External corrosion led to a through-wall defect causing the platform to be termporarily shut down. The operator required a permanent repair compliant ...
Repair demo to Ferric Chloride Pipe
Date Created: 7/22/2025
Industry: Food & Drink (FOOD)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products: Belzona 1212
Problem : A pipe run of some 20m has numerous leaks. The engineers are looking for a solution by repairing the pipe, rather than replacing it. A replacement wil...
Belzona SuperWrap Repairs vessel nozzles online
Date Created: 6/26/2017
Industry: Oil & Gas (OILG)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona 1111 Belzona 1983 Belzona 9381 Belzona 9382 Belzona 9111 Belzona 9611


Problem : Offshore platform vessel nozzles were corroded by CUI, and some small bore nozzles were leaking.
REGULATORY AGENCY ACCEPTS BELZONA SUPERWRAP II
Date Created: 11/29/2016
Industry: Oil & Gas (OILG)  |  Products:

Belzona 1982

Belzona 9381

Belzona 9382


Problem : The customer had a section of pipe with external corrosion problems and several through wall defects. Traditional cut and replace alternatives would r...
BELZONA SUPERWRAP II REPAIRS DRAIN LINES ON DEEPWATER PLATFORM
Date Created: 11/29/2016
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona 1111 (Super Metal)

Belzona Superwrap II


Problem : The drain line goes to the sump, which is the lowest point on the platform. If there is any oil spill or runoff, it could potentially get into the wat...
BELZONA SUPERWRAP II UPDATES RISER
Date Created: 9/11/2015
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona 1982 (SuperWrap II)

Belzona 9381 (Reinforcement Sheet)

Belzona 9382 (Release Film)

Belzona 1121 (Super XL-Metal)

Belzona 9111 (Cleaner Degreaser)


Problem : External corrosion was creating thin wall defective areas with potential loss of structural integrity. The asset owner wanted to restore the integrity...
Belzona SuperWrap II used for a pipe repair
Date Created: 7/23/2020
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super metal)

Belzona 9381 (SuperWrap II reinforcement sheet)

Belzona 1982 (SuperWrap II)

Belzona 9382 (Release film)


Problem : Underground pipe had developed thin-wall defect.
Belzona SuperWrap II Protects Pipelines for Chemical Plant
Date Created: 4/23/2020
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1511(Super HT-Metal)

Belzona SuperWrap Ⅱ


Problem : Corrosion and thinning of the auxiliary pipeline of the catalytic safety valve have affected the safe operation of the asset. To ensure the safe opera...
Belzona SuperWrap II Seals Deteriorated Pipe Coupling
Date Created: 3/11/2019
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzoa 4141 (Magma-Build)

Belzona SuperWrap II


Problem : The pipe coupling was buried and therefore suffered severe corrosion below the ground.
Underground Seawater Pipeline SuperWrapped with Belzona
Date Created: 10/30/2018
Industry: Fluid Flow (FLOW)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona SuperWrap II

Belzona 1982

Belzona 9381

Belzona 9382


Problem : Internal corrosion of pipeline and initial stages of weld degradation has been observed.
Emergency Repair to Boiler Water Pipe
Date Created: 8/9/2022
Industry: Power (POWR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super Metal)

Belzona SuperWrap II


Problem : The 600mm diameter pipe was heavily corroded resulting in several through wall defects.
Belzona repairs the suction part of a hydro turbine
Date Created: 1/22/2019
Industry: Water / Wastewater (WATR)  |  Application: ENC-Engines and Casings (ENC)  |  Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1331 

Belzona SuperWrap II


Problem : The internal surface of this hydro turbine presented an important loss of metal which ultimately led to a hole.
BELZONA RESTORES RISER OF OIL & GAS PRODUCTION PLATFORM
Date Created: 8/21/2015
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 1982 (SuperWrap II)

Belzona 9381 (Reinforcement Sheet)

Belzona 9382 (Release Film)

Belzona 9111 (Cleaner Degreaser)


Problem : Riser suffering from corrosion due to the offshore environment required the restoration of metal loss and protection from further deterioration. The a...
Belzona Strengthens Nozzles of Closed Drain Drum on Offshore Platform
Date Created: 8/12/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1511 (Super HT-Metal)

Belzona 1983 (Belzona Superwrap II Resin)

Belozna 9381

Belzona 9382

Belzona 9111 (Degreaser)


Problem : The nozzles of closed drain drum had developed thin-wall defect due to CUI.
Belzona Strengthens Nozzles of High-pressure Flare Scrubber on Offshore Platform
Date Created: 8/12/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1511 (Super HT- Metal)

Belzona 1983 (Belzona Superwrap II Resin)

Belzona 9381

Belzona 9382

Belzona 9111.


Problem : Due to the damage of the original insulation layer, the nozzle of the high-pressure flare scrubber was corroded under the insulation layer (CUI). The ...
Belzona Repairs Nozzles with Through-wall Defect Online on Offshore Platform
Date Created: 8/12/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super-Metal)

Belzona 1983 (Superwrap II Resin)

Belozna 9381

Belzona 9382

Belzona 9111 (Degreaser)

Belzona 9611


Problem : The nozzles of closed drain drum had developed thin-wall defect and through-wall defect due to CUI.
Belzona Restores Nozzles of Closed Drain Drum Online on Offshore Platform
Date Created: 8/12/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1511 (Super-HT Metal)

Belzona 1983 (Belzona Superwrap II Resin)

Belzona 9381

Belzona 9382

Belzona 9111 (Degreaser)


Problem : The nozzles of closed drain tank had developed thin-wall defect due to CUI.
NON-COMPLIANT WRAP KEEPS 30" LINE IN SERVICE
Date Created: 12/2/2013
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super Metal)

Belzona 9341 (Reinforcement Tape)

Belzona 1971 (Superwrap Conditioner)

Belzona 9371 (Superwrap Reinforcement Sheet)

Belzona 5811 (Immersion Grade)


Problem : Holes and thin wall.
Belzona SuperWrap II Repair on 2in. Elbow - LDHI Transfer Line
Date Created: 10/27/2021
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 9611

Belzona 9111

Belzona 1161

Belzona 1982

Belzona 9381

Belzona 9382 


Problem : The problem was a pin hole leak that was found on a 2" pipe around the weld seam of an elbow, caused by external corrosion. This was an LDHI transfer ...
Belzona Super Wrap II on High Pressure Pipe Offshore
Date Created: 10/26/2022
Industry: Oil & Gas (OILG)  |  Application: SOS-Ships and Offshore Structures (SOS)  |  Products: Belzona 9111 Cleaner/Degreaser Belzona 1161 Super UW Metal Belzona 1982 Resin Belzona 9381 84mm Belzona 9382 Red Release Film Belzona mixing tools
Problem : The pipe is a very important part of oil & gas operations for this customer. The application area was difficult to access. External corrosion created ...
Belzona saves Ruptured Effluent Tank
Date Created: 12/3/2018
Industry: Food & Drink (FOOD)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 9611 ES Metal Stick

Belzona Superwrap II plates

Belzona 1212


Problem : The problem that the customer had was that the effluent treatment tank had multiple leaks, both into the surrounding soil, and into a bund. To avoid b...
Belzona helps in the Restoration of an Irrigation Pipeline
Date Created: 7/3/2019
Industry: Fluid Flow (FLOW)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 1982 (SuperWrap 2)

Belzona 9381 

Belzona 5821 


Problem : The internal walls of the pipeline were suffering from serve corrosion and wear over time. Outright replacement of the pipe wasn't an option as the pi...
Steel panel tanks suffering from corrosion
Date Created: 4/23/2025
Industry: Water / Wastewater (WATR)  |  Application: TCC-Tanks and Chemical Containment Areas (TCC)  |  Products: Belzona 1111 (Super Metal), Belzona 3131 (WG Membrane)
Problem : A wastewater site with typical glass-infused steel panel tanks were experiencing leaks due to internal chemical attack and environmental exposure, res...
Structural Reinforcement of Process Lines with Belzona SW II
Date Created: 11/18/2019
Industry: ()  |  Products:

Belzona 9611

Belzona 1111 (Supermetal)

Belzona 1981 (Superwrap II)

Belzona 9381 (Carbon Fiber Reinforcement)

Belzona 9382 (Release Film)


Problem : Lines suffering from thin and through wall defects due to its internal corrosion process. Internal temperature was 20°C with pressures up to 0.15 MPa....
Strengthening Corroded Storage Tank With Belzona
Date Created: 1/12/2021
Industry: Chemical & Petrochemical (PETR)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1111 (Super-Metal)

Belzona 1981 (Superwrap II)

Belzona 9381

Belzona 9382

Belzona 5811 (Immersion Grade)


Problem : Numerous areas of the tank had a loss of thickness due to corrosion.
BELZONA SAVES OFFSHORE OIL & GAS PLATFORM FROM SHUTDOWN
Date Created: 9/18/2013
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 4141 (Magma-Build)

Belzona 4151 (Magma-Quartz Resin)

Belzona 9371 (Superwrap Reinforcement Sheet)

Belzona 9111 (Cleaner Degreaser)


Problem : Leaking natural gas caused safety and environmental problems. The platform was subject to a forced shut-in for non-compliance of federal regulations. ...
BELZONA HELPS PLATFORM QUALIFYING FOR PLUG & ABANDON PROJECT
Date Created: 9/18/2013
Industry: Oil & Gas (OILG)  |  Application: VPF-Valves, Pipes and Fittings (VPF)  |  Products:

Belzona 1121 (Super XL-Metal)

Belzona 4141 (Magma-Build)

Belzona 9371 (Superwrap Reinforcement Sheet)

Belzona 4151 (Magma-Quartz Resin)

Belzona 9111 (Cleaner Degreaser)


Problem : External/Internal corrosion caused many hole through defects. Conventional welding would have been very time consuming and expensive. Additionally, a ...

Still Didn’t Find Your Answer?

Please contact Belzona if you wish to find out more about our products and/or our services.

Contact us